NH033x-L and NH050x-L Series Power Modules:  
5 Vdc Input; 1.2 Vdc to 3.3 Vdc Output; 10 A and 15 A  
Data Sheet  
March 2010  
Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-  
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess  
of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended  
periods can adversely affect device reliability.  
Parameter  
Input Voltage (continuous)  
On/Off Terminal Voltage  
Device  
All  
Symbol  
VI  
Min  
Max  
7.0  
Unit  
Vdc  
Vdc  
All  
Von/off  
6.0  
Operating Ambient Temperature*:  
NH033x-L  
All  
All  
TA  
TA  
0
0
62  
49  
°C  
°C  
NH050x-L  
Storage Temperature  
All  
Tstg  
–55  
125  
°C  
* Forced convection—200 lfpm minimum. Higher ambient temperatures possible with increased airflow and/or decreased power output. See the  
Thermal Considerations section for more details.  
Electrical Specifications  
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature  
conditions.  
Table 1. Input Specifications  
Parameter  
Operating Input Voltage:  
Symbol  
Min  
Typ  
Max  
Unit  
Start-up  
Continuous Operation  
VI  
VI  
4.75  
4.5  
5.0  
5.5  
Vdc  
Vdc  
Maximum Input Current  
(VI = 0 V to 5.5 V; IO = IO, max; see Figures 1—8.):  
NH033x-L  
NH050x-L  
II, max  
II, max  
10  
16  
A
A
Input Reflected-ripple Current, Peak-to-peak  
(5 Hz to 20 MHz, 500 nH source impedance;  
see Figure 33.)  
II  
300  
mAp-p  
Input Ripple Rejection (120 Hz)  
60  
dB  
Fusing Considerations  
CAUTION: This power module is not internally fused. An input line fuse must always be used.  
This power module can be used in a wide variety of applications, ranging from simple stand-alone operation to an  
integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not  
included; however, to achieve maximum safety and system protection, always use an input line fuse. The safety  
agencies require a normal-blow fuse with a maximum rating of 20 A (see Safety Considerations section). Based on  
the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse  
with a lower rating can be used. Refer to the fuse manufacturer’s data for further information.  
2
Lineage Power