欢迎访问ic37.com |
会员登录 免费注册
发布采购

QRW035A0G1Z 参数 Datasheet PDF下载

QRW035A0G1Z图片预览
型号: QRW035A0G1Z
PDF下载: 下载PDF文件 查看货源
内容描述: 36 VDC - 75 VDC输入, 1.0〜 12 Vdc输出; 10 A至40 A [36 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A]
分类和应用:
文件页数/大小: 36 页 / 957 K
品牌: LINEAGEPOWER [ LINEAGE POWER CORPORATION ]
 浏览型号QRW035A0G1Z的Datasheet PDF文件第1页浏览型号QRW035A0G1Z的Datasheet PDF文件第3页浏览型号QRW035A0G1Z的Datasheet PDF文件第4页浏览型号QRW035A0G1Z的Datasheet PDF文件第5页浏览型号QRW035A0G1Z的Datasheet PDF文件第6页浏览型号QRW035A0G1Z的Datasheet PDF文件第7页浏览型号QRW035A0G1Z的Datasheet PDF文件第8页浏览型号QRW035A0G1Z的Datasheet PDF文件第9页  
Data Sheet
June 15,
2009
QRW010/025/035/040 Series Power Modules; dc-dc Converters
36 Vdc - 75 Vdc Input, 1.0 to 12 Vdc Output; 10 A to 40 A
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress
ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the
operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the
device reliabiltiy.
Parameter
Input Voltage:Continuous
Transient (100ms)
Operating Ambient Temperature
(See Thermal Considerations section)
Storage Temperature
I/O Isolation Voltage (100% factory Hi-Pot tested)
When using optional case ground pin
(option 7)
Device
All
All
All
Symbol
VI
VI, trans
TA
Tstg
Min
–40
–55
1500
700
Max
80
100
85
125
Vdc
Vdc
Unit
Vdc
Vdc
°C
°C
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter
Operating Input Voltage
Maximum Input Current
(VI = 0 V to 75 V; IO = IO, max)
Inrush Transient
Input Reflected Ripple Current, peak-peak
(5 Hz to 20 MHz, 12 µH source impedance
See Test configuration section)
Input Ripple Rejection (120 Hz)
Device
All
All
All
All
Symbol
VIN
Min
36
Typ
48
Max
75
4.5
1
Unit
Vdc
Adc
A
2
s
mAp-p
I
2
t
16
All
60
dB
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple stand-alone operation to an integrated
part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve
maximum safety and system protection, always use an input line fuse. The safety agencies require a normal-blow fuse with a
maximum rating of 10 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush
energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s
data for further information.
Lineage Power
2