ID100 ID101
Linear Integrated Systems
FEATURES
DIRECT REPLACEMENT FOR INTERSIL ID100 & ID101
REVERSE LEAKAGE CURRENT
REVERSE BREAKDOWN VOLTAGE
REVERSE CAPACITANCE
ABSOLUTE MAXIMUM RATINGS
1
@ 25 °C (unless otherwise stated)
Maximum Temperatures
Storage Temperature
Operating Junction Temperature
Maximum Power Dissipation
Continuous Power Dissipation
Maximum Currents
Forward Current
Reverse Current
Maximum Voltages
Reverse Voltage
Diode to Diode Voltage
30V
±50V
20mA
100µA
300mW
-65 to +200 °C
-55 to +150 °C
I
R
= 0.1pA
BV
R
≥
30V
C
rss
= 0.75pF
ID100
ID101
MONOLITHIC DUAL
PICO AMPERE DIODES
TO-78
BOTTOM VIEW
NC
A1
K1
2
1
7
3
5
6
TO-71
BOTTOM VIEW
NC
A1
K1
2
1
7
3
5
6
NC
A2
K2
NC
A2
K2
ELECTRICAL CHARACTERISTICS @ 25 °C (unless otherwise stated)
SYMBOL
BV
R
V
F
I
R
|I
R1
-I
R2
|
C
rss
CHARACTERISTIC
Reverse Breakdown Voltage
Forward Voltage
Reverse Leakage Current
Differential Leakage Current
Total Reverse Capacitance
2
0.75
MIN
30
0.8
0.1
2.0
10
3
1
pF
pA
1.1
TYP
MAX UNITS
V
CONDITIONS
I
R
= 1µA
I
F
= 10mA
V
R
= 1V
V
R
= 10V
V
R
= 10V,
f
= 1MHz
Linear Integrated Systems
• 4042 Clipper Court • Fremont, CA 94538 • Tel: 510 490-9160 • Fax: 510 353-0261