欢迎访问ic37.com |
会员登录 免费注册
发布采购

LTC3788-1 参数 Datasheet PDF下载

LTC3788-1图片预览
型号: LTC3788-1
PDF下载: 下载PDF文件 查看货源
内容描述: 多相同步升压控制器 [PolyPhase Synchronous Boost Controller]
分类和应用: 控制器
文件页数/大小: 36 页 / 358 K
品牌: LINEAR [ LINEAR INTEGRATED SYSTEMS ]
 浏览型号LTC3788-1的Datasheet PDF文件第5页浏览型号LTC3788-1的Datasheet PDF文件第6页浏览型号LTC3788-1的Datasheet PDF文件第7页浏览型号LTC3788-1的Datasheet PDF文件第8页浏览型号LTC3788-1的Datasheet PDF文件第10页浏览型号LTC3788-1的Datasheet PDF文件第11页浏览型号LTC3788-1的Datasheet PDF文件第12页浏览型号LTC3788-1的Datasheet PDF文件第13页  
LTC3787
TYPICAL PERFORMANCE CHARACTERISTICS
Maximum Current Sense
Threshold vs Duty Cycle
MAXIMUM CURRENT SENSE VOLTAGE (mV)
120
CHARGE PUMP CHARGING CURRENT (μA)
100
80
60
40
20
0
0
10 20 30 40 50 60 70 80 90 100
DUTY CYCLE (%)
3787 G25
Charge Pump Charging Current
vs Operating Frequency
80
80
T = – 60°C
T = – 45°C
T = 25°C
T = 130°C
T = 155°C
CHARGE PUMP CHARGING CURRENT (μA)
70
60
50
40
30
20
10
0
70
60
50
40
30
20
10
0
50
150 250 350 450 550 650 750
OPERATING FREQUENCY (kHz)
3787 G26
Charge Pump Charging Current
vs Switch Voltage
FREQ = GND
FREQ = INTV
CC
I
LIM
= INTV
CC
I
LIM
= FLOAT
I
LIM
= GND
5
10
15
25
30
20
SWITCH VOLTAGE (V)
35
40
3787 G27
PIN FUNCTIONS
(QFN/SSOP)
FREQ (Pin 1/Pin 4):
Frequency Control Pin for the Internal
VCO. Connecting the pin to GND forces the VCO to a fixed
low frequency of 350kHz. Connecting the pin to INTV
CC
forces the VCO to a fixed high frequency of 535kHz. The
frequency can be programmed from 50kHz to 900kHz
by connecting a resistor from the FREQ pin to GND. The
resistor and an internal 20μA source current create a volt-
age used by the internal oscillator to set the frequency.
Alternatively, this pin can be driven with a DC voltage to
vary the frequency of the internal oscillator.
PHASMD (Pin 2/Pin 5):
This pin can be floated, tied to
SGND, or tied to INTV
CC
to program the phase relationship
between the rising edges of BG1 and BG2, as well as the
phase relationship between BG1 and CLKOUT.
CLKOUT (Pin 3/Pin 6):
A Digital Output Used for Daisy-
chaining Multiple LTC3787 ICs in Multiphase Systems. The
PHASMD pin voltage controls the relationship between BG1
and CLKOUT. This pin swings between SGND and INTV
CC
.
PLLIN/MODE (Pin 4/Pin 7):
External Synchronization Input
to Phase Detector and Forced Continuous Mode Input.
When an external clock is applied to this pin, it will force
the controller into forced continuous mode of operation
and the phase-locked loop will force the rising BG1 signal
to be synchronized with the rising edge of the external
clock. When not synchronizing to an external clock, this
input determines how the LTC3787 operates at light loads.
Pulling this pin to ground selects Burst Mode operation.
An internal 100k resistor to ground also invokes Burst
Mode operation when the pin is floated. Tying this pin
to INTV
CC
forces continuous inductor current operation.
Tying this pin to a voltage greater than 1.2V and less than
INTV
CC
– 1.3V selects pulse-skipping operation. This can
be done by adding a 100k resistor between the PLLIN/
MODE pin and INTV
CC
.
SGND (Pin 5/Pin 8):
Signal Ground. All small-signal
components and compensation components should
connect to this ground, which in turn connects to PGND
at a single point.
RUN (Pin 6/Pin 9):
Run Control Input. Forcing this pin
below 1.28V shuts down the controller. Forcing this pin
below 0.7V shuts down the entire LTC3787, reducing
quiescent current to approximately 8μA. An external
resistor divider connected to V
IN
can set the threshold
for converter operation. Once running, a 4.5μA current is
sourced from the RUN pin allowing the user to program
hysteresis using the resistor values.
3787fc
9