欢迎访问ic37.com |
会员登录 免费注册
发布采购

LTC4413 参数 Datasheet PDF下载

LTC4413图片预览
型号: LTC4413
PDF下载: 下载PDF文件 查看货源
内容描述: 独立250毫安锂离子电池充电器的2×2 DFN [Standalone 250mA Li-Ion Battery Charger in 2 × 2 DFN]
分类和应用: 电池
文件页数/大小: 18 页 / 183 K
品牌: LINEAR [ LINEAR INTEGRATED SYSTEMS ]
 浏览型号LTC4413的Datasheet PDF文件第1页浏览型号LTC4413的Datasheet PDF文件第2页浏览型号LTC4413的Datasheet PDF文件第3页浏览型号LTC4413的Datasheet PDF文件第5页浏览型号LTC4413的Datasheet PDF文件第6页浏览型号LTC4413的Datasheet PDF文件第7页浏览型号LTC4413的Datasheet PDF文件第8页浏览型号LTC4413的Datasheet PDF文件第9页  
LTC4065L/
LTC4065LX/LTC4065L-4.1
The
l
denotes specifications which apply over the full operating
temperature range, otherwise specifications are T
A
= 25°C. V
CC
= 5V, V
BAT
= 3.8V, V
EN
= 0V unless otherwise specified. (Note 2)
SYMBOL PARAMETER
I
CHRG
I
C/10
T
LIM
R
ON
f
BADBAT
D
BADBAT
CHRG
Pin Input Current
End of Charge Indication Current Level
Junction Temperature in Constant
Temperature Mode
Power FET “ON” Resistance
(Between V
CC
and BAT)
Defective Battery Detection
CHRG
Pulse Frequency
Defective Battery Detection
CHRG
Pulse Frequency Duty Ratio
I
BAT
= 150mA
CONDITIONS
V
BAT
= 4.5V, V
CHRG
= 5V
R
PROG
= 1.33k (Note 5)
l
l
ELECTRICAL CHARACTERISTICS
MIN
0.08
TYP
0
0.095
115
1.5
2
75
MAX
1
0.11
UNITS
μA
mA/mA
°C
Ω
Hz
%
Note 1:
Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
Note 2:
The LTC4065L is tested under pulsed load conditions such that
T
J
≈ T
A
. The LTC4065L is guaranteed to meet performance specifica-
tions from 0°C to 70°C. Specifications over the –40°C to 85°C operating
temperature range are assured by design, characterization and correlation
with statistical process controls.
Note 3:
Failure to solder the exposed backside of the package to the PC
board ground plane will result in a thermal resistance much higher than
rated.
Note 4:
Although the LTC4065L functions properly at 3.75V input, full
charge current requires an input voltage greater than the desired final bat-
tery voltage per the ΔV
UVCL1
specification.
Note 5:
I
C/10
is expressed as a fraction of measured full charge current
with indicated PROG resistor.
Note 6:
This IC includes overtemperature protection that is intended
to protect the device during momentary overload conditions. Junction
temperature will exceed 125°C when overtemperature protection is active.
Continuous operation above the specified maximum operating junction
temperature may impair device reliability.
Note 7:
This parameter is not applicable to the LTC4065LX.
4065lfb
4