LT6700/LT6700HV
ELECTRICAL CHARACTERISTICS
SYMBOL PARAMETER
I
S
Supply Current
The
l
denotes the specifications which apply over the temperature range of –40°C ≤ T
A
≤ 85°C, (LT6700HVI-1/LT6700HVI-2/LT6700HVI-3)
unless otherwise specified (Notes 4, 5).
CONDITIONS
No Load Current
V
S
= 1.4V
V
S
= 5V
V
S
= 12V
V
S
= 18V
l
l
l
l
MIN
TYP
MAX
14.0
15.0
16.5
17.0
UNITS
µA
µA
µA
µA
The
l
denotes the specifications which apply over the temperature range of –40°C ≤ T
A
≤ 125°C, (LT6700HVH-1/LT6700HVH-2/
LT6700HVH-3) unless otherwise specified (Notes 4, 5).
SYMBOL PARAMETER
V
TH(R)
Rising Input Threshold Voltage
(Note 6)
CONDITIONS
R
L
= 100k, V
O
= 2V Swing
V
S
= 1.4V
V
S
= 5V
V
S
= 12V
V
S
= 18V
R
L
= 100k, V
O
= 2V Swing
V
S
= 1.4V
V
S
= 5V
V
S
= 12V
V
S
= 18V
V
S
= 1.4V, 5V, 12V, 18V, R
L
= 100k, V
O
= 2V Swing
V
S
= 1.4V, 18V, V
IN
= V
S
V
S
= 1.4V, V
IN
= 18V, 36V
V
S
= 1.4V, 18V, V
IN
= 100mV
10mV Input Overdrive
V
S
= 1.4V, I
OUT
= 0.1mA
V
S
= 1.6V, I
OUT
= 3mA
V
S
= 5V, I
OUT
= 5mA
V
S
= 1.4V, 18V, V
OUT
= V
S
, V
IN
= 40mV Overdrive
V
S
= 18V, V
OUT
= 18V, (36V, R
L
= 100k), V
IN
= 40mV Overdrive
No Load Current
V
S
= 1.4V
V
S
= 5V
V
S
= 12V
V
S
= 18V
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
LT6700H
MIN
TYP
MAX UNITS
390
392
389
388
381.5
382.5
380.5
379.5
2
411
410
412
413
405.5
404.5
406.5
407.5
13.5
±45
±45
±50
250
250
250
1
1
16.0
17.0
18.5
19.0
mV
mV
mV
mV
mV
mV
mV
mV
mV
nA
nA
nA
mV
mV
mV
µA
µA
µA
µA
µA
µA
V
TH(F)
Falling Input Threshold Voltage
(Note 6)
HYS
I
B
V
OL
HYS = V
TH(R)
– V
TH(F)
Input Bias Current
Output Low Voltage
I
OFF
I
S
Output Leakage Current
Supply Current
Note 1:
Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
Note 2:
A heat sink may be required to keep the junction temperature
below the absolute maximum rating when the output is shorted
indefinitely.
Note 3:
The inputs are protected by ESD diodes to the ground. If the input
voltage exceeds –0.3V below ground, the input current should be limited
to less than 10mA.
Note 4:
The LT6700C-1/-2/-3/LT6700HVC-1/-2/-3, and
LT6700I-1/-2/-3/LT6700HVI-1/-2/-3 are guaranteed functional over the
operating temperature range of – 40°C to 85°C. The LT6700H-1/-2/-3/
LT6700HVH-1/-2/-3 is guaranteed functional over the operating
temperature range of –40°C to 125°C. The LT6700MP-1/-2/-3 is
guaranteed functional over the operating temperature range of –55°C to
125°C.
Note 5:
The LT6700C-1/-2/-3/LT6700HVC-1/-2/-3 is guaranteed to
meet the specified performance from 0°C to 70°C. The LT6700C-1/-2/-
3/LT6700HVC-1/-2/-3 are designed, characterized and expected to meet
specified performance from – 40°C to 85°C but are not tested or QA
sampled at these temperatures. The LT6700I-1/-2/-3/LT6700HVI-1/-2/-3
is guaranteed to meet specified performance from –40°C to 85°C. The
LT6700H-1/-2/-3/LT6700HVH-1/-2/-3 is guaranteed to meet specified
performance from –40°C to 125°C.The LT6700MP-1/-2/-3 is guaranteed to
meet specified performance from –55°C to 125°C.
Note 6:
V
TH
defines the threshold voltage of the comparators and
combines the effect of offset and reference accuracy.
6700123fh
For more information
www.linear.com/LT6700
9