LTC1485  
PPLICATI  
O U  
W
U
A
S I FOR ATIO  
10  
Thermal Shutdown  
The LTC1485 has a thermal shutdown feature which  
protects the part from excessive power dissipation. If the  
outputs of the driver are accidentally shorted to a power  
supply or low impedance source, up to 250mA can flow  
through the part. The thermal shutdown circuit disables  
the driver outputs when the internal temperature reaches  
150°C and turns them back on when the temperature  
cools to 130°C. If the outputs of two or more LTC1485  
drivers are shorted directly, the driver outputs can not  
supply enough current to activate the thermal shutdown.  
Thus, the thermal shutdown circuit will not prevent con-  
tention faults when two drivers are active on the bus at the  
same time.  
1
0.1  
0.1  
1
10  
100  
FREQUENCY (MHz)  
1485 F10  
Figure 10. Attenuation vs Frequency for Belden 9481  
10k  
Cables and Data Rate  
The transmission line of choice for RS485 applications is  
a twisted pair. There are coaxial cables (twinaxial) made  
for this purpose that contain straight pairs, but these are  
less flexible, more bulky, and more costly than twisted  
pairs. Many cable manufacturers offer a broad range of  
120cables designed for RS485 applications.  
1k  
100  
10  
Losses in a transmission line are a complex combination  
of DC conductor loss, AC losses (skin effect), leakage, and  
AC losses in the dielectric. In good polyethylene cables  
such as the Belden 9841, the conductor losses and dielec-  
tric losses are of the same order of magnitude, leading to  
relatively low overall loss (Figure 10).  
2.5M  
10k  
100k  
DATA RATE (bps)  
1M  
10M  
1485 F11  
Figure 11. Cable Length vs Data Rate  
end of the cable, since this eliminates the possibility of  
gettingreflectionsfromtwodirections.Simplylookatthe  
driver output while transmitting square wave data. If the  
cable is terminated properly, the waveform will look like  
a square wave (Figure12).  
When using low loss cables, Figure 11 can be used as a  
guidelineforchoosingthemaximumlinelengthforagiven  
data rate. With lower quality PVC cables the dielectric loss  
factor can be 1000 times worse. PVC twisted pairs have  
terrible losses at high data rates (>100kbs), and greatly  
reduce the maximum cable length. At low data rates  
however, theyareacceptableandmuchmoreeconomical.  
If the cable is loaded excessively (47) the signal initially  
sees the surge impedance of the cable and jumps to an  
initial amplitude. The signal travels down the cable and is  
reflectedbackoutofphasebecauseofthemistermination.  
When the reflected signal returns to the driver, the ampli-  
tude will be lowered. The width of the pedestal is equal to  
twice the electrical length of the cable (about 1.5ns/foot).  
If the cable is lightly loaded (470) the signal reflects in  
phase and increases the amplitude at the driver output. An  
input frequency of 30kHz is adequate for tests out to 4000  
feet of cable.  
Cable Termination  
The proper termination of the cable is very important. If  
the cable is not terminated with its characteristic imped-  
ance, distorted waveforms will result. In severe cases,  
distorted (false) data and nulls will occur. A quick look at  
the output of the driver will tell how well the cable is  
terminated. It is best to look at a driver connected to the  
8