欢迎访问ic37.com |
会员登录 免费注册
发布采购

LTC3207EUF-1-TRPBF 参数 Datasheet PDF下载

LTC3207EUF-1-TRPBF图片预览
型号: LTC3207EUF-1-TRPBF
PDF下载: 下载PDF文件 查看货源
内容描述: 600毫安通用多路输出LED / CAM驱动器 [600mA Universal Multi-Output LED/CAM Driver]
分类和应用: 驱动器
文件页数/大小: 20 页 / 237 K
品牌: Linear [ Linear ]
 浏览型号LTC3207EUF-1-TRPBF的Datasheet PDF文件第5页浏览型号LTC3207EUF-1-TRPBF的Datasheet PDF文件第6页浏览型号LTC3207EUF-1-TRPBF的Datasheet PDF文件第7页浏览型号LTC3207EUF-1-TRPBF的Datasheet PDF文件第8页浏览型号LTC3207EUF-1-TRPBF的Datasheet PDF文件第10页浏览型号LTC3207EUF-1-TRPBF的Datasheet PDF文件第11页浏览型号LTC3207EUF-1-TRPBF的Datasheet PDF文件第12页浏览型号LTC3207EUF-1-TRPBF的Datasheet PDF文件第13页  
LTC3207/LTC3207-1  
OPERATION  
Mode Switching  
The current source is disabled when this section receives  
an all zero data word. The supply current for the current  
source is reduced to zero.  
The LTC3207/LTC3207-1 will automatically switch from  
1x mode to 1.5x mode and subsequently to 2x mode  
whenever a dropout condition is detected at an LED pin.  
Dropout occurs when an active current source voltage  
becomes too low for the programmed current to be sup-  
plied. The mode change will not occur unless dropout  
has existed for approximately 400µs. This delay will allow  
the LEDs to warm up and achieve the final LED forward  
voltage value.  
CAMHL  
The CAMHL pin quickly selects the camera high register  
2
for flash applications without re-accessing the I C port.  
When low, the CAM current range will be controlled by  
the camera low 4-bit register. When CAMHL is asserted  
high, the current range will be set by the camera high 4-bit  
register. The charge pump mode will be reset to 1x on the  
falling edge of CAMHL.  
The mode will automatically switch back to 1x whenever  
a register is updated via the I C port, when gradation  
completes ramping down, on the falling edge of either  
ENU or CAMHL and after each blink period.  
2
A safety timer will disable the CAM output after two sec-  
onds whenever the high current mode is selected. To reset  
the safety timer, the CAMHL signal from the external pin  
The part can be forced to operate in 1x, 1.5x or 2x mode  
by writing the appropriate bits into REG0. This feature  
may be used for powering loads from CPO.  
2
or through the I C port is set low. Alternatively the CAM  
register can be written to all zeroes. If unused, the pin  
should be connected to ground.  
Nonprogrammed current sources do not affect dropout.  
In addition, ENU controlled current sources do not affect  
dropout when ENU is low.  
Blinking  
Each universal output (ULED1 to ULED12) can be set to  
blink 0.156s or 0.625s with a period of 1.25s or 2.5s via  
2
Universal Current Sources (ULED1 to ULED12)  
the I C port. The blinking rate is selected via REG15 and  
ULED outputs are selected via REG1 to REG12. Blinking  
andgradationratesareindependent.Blinkresetsthecharge  
pump to 1x mode after each period. Please refer to Ap-  
plication Note 108 for detailed information and examples  
on programming blinking.  
There are twelve universal 27.5mA current sources. Each  
current source has a 6-bit linear DAC for current control.  
The output current range is 0 to full-scale in 64 steps.  
Each current source is disabled when an all zero data word  
is written. The supply current for that source is reduced  
to zero. Connect unused outputs to ground.  
Gradation  
ULED1 to ULED12 can also be used as general purpose  
outputs (GPO). Current sources in the GPO mode can be  
Universal LED outputs ULED1 to ULED12 can be set to  
have the current ramp up and down at 0.24s, 0.48s and  
2
2
used as I C controlled open-drain drivers. The GPO mode  
0.96s rates via the I C port. The total gradation period is  
is selected by programming REG1 to REG12, Bit 6 and  
Bit 7 to a logic one. In the GPO mode dropout detection  
is disabled, output swings to ground will not cause mode  
switching.  
longer than the ramp time since there is a region at the  
start and end where the ULED current does not change.  
A new gradation period cannot be started until after the  
previousgradationperiodhasended.Eachoftheseoutputs  
can have either blinking or gradation enabled. The grada-  
tion time is set via REG15 and ULED outputs are selected  
via REG1 to REG12. The ramp direction is controlled via  
REG0. Setting the UP bit high causes gradation to ramp  
up; setting this bit low causes gradation to ramp down.  
Please refer to Application Note 108 for detailed informa-  
Camera Current Source  
There is one CAM current source. This current source has  
a 4-bit linear DAC for current control. The output current  
range is 0mA to 425mA in 16 steps.  
tion and examples on programming gradation.  
3207fc  
9