LAL2014-52
Broadband Access Transformer
Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation
RoHS Compliant
Operating Temperature -40°C to 85°C
Electrical Specifications @25℃
OCL:
Leakage
Inductance:
Interwinding
Capacitance
PIN 16-9= 2.0mH ±10% @ 10KHz/0.1V/Ser. (PIN 11-14 Short)
PIN 1-4= 3.0uH Max. @ 100KHz/0.1V (PIN 2-3,5-6-7-8,9-11-14-16 Short)
PIN 5-8= 20uH Max. @ 100KHz/0.1V (PIN 6-7,1-2-3-4,9-11-14-16 Short)
PIN 1-16= 15pF Max. @ 100KHz/0.1V (PIN 2-3,PIN 11-14 Short)
PIN 5-16= 15pF Max. @ 100KHz/0.1V (PIN 6-7,PIN 11-14 Short)
PIN 1-8= 60pF Max. @ 100KHz/0.1V
T.H.D
(PIN 2-3,PIN 6-7 Short)
PIN 16-9 to PIN 1-4 –82dB Max. @ 30KHz/3.162V (PIN 11-14,PIN 2-3 Short)
PIN 16-9 to PIN 5-8= -82dB Max. @ 30KHz/3.162V (PIN 11-14,PIN 6-7 Short)
PIN 16-9 = 1050 mohm Max. (PIN 11-14 Short)
PIN 1-4 = 585 mohm Max. (PIN 2-3 Short)
PIN 5 -8 = 2.2 ohm Max.
Hi-POT :
Turn Ratio:
(PIN 6-7 Short)
PRI. – SEC. =1875VAC/60Hz/2Seconds/1mA
PIN16-9 : PIN 1-4 = 4.25±2% :1 ( PIN 11-14,PIN 2-3 Short)
PIN16-9 : PIN 5-8 = 1±2% :1 ( PIN 11-14,PIN 6-7 Short)
D.C.R
Dimensions
(Units: mm)
Schematic
LAL2014
LinkCom
Date Code -52 G
Mark
1.LAL****----LAL2014
2. X----PRODUCT LINE
3. DATE CODE----YYWW
TOP VIEW
4. G----RoHS
SUGGESTED PADS LAYOUT
Rev.F