LAL2066-50
Broadband Access Transformer
Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation and
250V working voltage
RoHS Compliant
Excellent THD performance
Operating Temperature -40°C to 85°C
Electrical Specifications @25℃
OCL:
Leakage
Inductance:
IInterwinding
Capacitance
T.H.D
D.C.R:
Hi-POT :
Turn Ratio:
PIN 16-9= 200uH ±10% @ 10KHz/0.1V/Ser.
PIN 16-9= 30uH Max.
PIN 16-1= 50 pF Max.
PIN 16-5= 80 pF Max.
@ 100Hz/100mV
@ 100KHz/100mV
@ 100KHz/100mV
PIN 16-9= 30uH Max. @ 100Hz/100mV
PIN 16-9 to PIN 1-4= -80dB Max. @ 30KHz/2V
PIN 16-9 to PIN 5-8= -80dB Max. @ 30KHz/2V
PIN 1-4 = 10 ohm Max.
PIN 5-8 = 2.0 ohm Max.
PIN 16-9 = 5.0 ohm Max.
PRI. – SEC. =1875VAC/60Hz/2Seconds/1mA
PIN16-9 : PIN 1-4 = 1±2% :1
PIN16-9 : PIN 5-8 = 3.8±2% :1
Dimensions
(Units: mm)
5.1±0.3
3.4±0.3
0.7TYP.
5.10
3.40
3.40
1.70
Schematic
SEC
1
Rx
3
2
4
5
Tx
1.70
1.00
SUGGESTED PAD LAYOUT
PRI
16
14.0
F
19.0
LinkCom
X DATE CODE G
14.4±0.5
LAL
****
11
14
LINE
0.5TYP.
13.5±0.5
G
1.7±0.3
PIN1
7
6
8
9
A
12.6±0.5
C
13.5±0.5
Mark
1.LAL****----LAL2066
2. X----PRODUCT LINE
3. DATE CODE----YYWW
4. G----RoHS
+1.00
-0.50
12.5
B
+0.15
-0.10
D
13.0±0.5
0.3
15.5±0.5
E 17.0
+1.0
-0.5
Form Ver. A