LITE-ON
Electrical
Optical
Characteristics
Symbol
TECHNOLOGY
At
Ta=25
℃
Min.
Typ.
CORPORATION
Property of Lite-On Only
Parameter
Part No.
LTST-
Max.
Unit
Test Condition
IF = 20mA
Note 1
Luminous Intensity
IV
C230KRKT
18.0
54.0
mcd
Viewing Angle
2
θ
1/2
C230KRKT
130
deg
Note 2 (Fig.6)
Peak Emission Wavelength
λ
P
C230KRKT
639
nm
Measurement
@Peak (Fig.1)
Dominant Wavelength
λ
d
C230KRKT
631
nm
Note 3
Spectral Line Half-Width
Δλ
C230KRKT
20
nm
Forward Voltage
VF
C230KRKT
2.0
2.4
V
IF = 20mA
Reverse Current
IR
C230KRKT
10
μ
A
VR = 5V
Capacitance
C
C230KRKT
40
PF
VF = 0
f = 1MHZ
Notes: 1. Luminous intensity is measured with a light sensor and filter combination that approximates the
CIE eye-response curve.
2.
θ
1/2 is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
3. The dominant wavelength,
λ
d is derived from the CIE chromaticity diagram and represents the
single wavelength which defines the color of the device.
Part
No. : LTST-C230KRKT
Page :
4
of
11
BNS-OD-C131/A4