PARTIAL DISCHARGE TEST METHOD
Method (A) for type testing and random testing.
V
V
INTIAL
V
pr
V
IORM
t1, t2
= 1 to 10s
t3, t4
= 1s
tp (Partial Discharge Measuring Time)= 60s
tb
= 62s
tini
= 10s
t3
t1 t
ini
t2
tp
tb
t4
t
Method (B) for routine testing.
V
V
pr
V
IORM
t3, t4
= 0.1s
tp (Partial Discharge Measuring Time)= 1s
tb
= 1.2s
t3
tp
tb
t4
t
The partial discharge level shall not exceed 5 pC during the partial discharge measuring time
interval t
p
under the test conditions shown above.