ELECTRICAL CHARACTERISTICS
@ T
A=
25
℃
unless otherwise specified
TB0640L thru TB3500L
PARAMETER
RATED
REPETITIVE
OFF-STATE
VOLTAGE
OFF-STATE
LEAKAGE
CURRENT
@ V
DRM
BREAKOVER
VOLTAGE
ON-STATE
VOLTAGE
@ I
T
=1.0A
BREAKOVER
CURRENT
HOLDING
CURRENT
OFF-STATE
CAPACITANCE
SYMBOL
UNITS
V
DRM
Volts
I
DRM
uA
V
BO
Volts
V
T
Volts
I
BO
-
mA
I
BO+
mA
I
H-
mA
I
H+
mA
Co
pF
LIMIT
Max
Max
Max
Max
Min
Max
Min
Max
Typ
TB0640L
TB0720L
TB0900L
TB1100L
TB1300L
TB1500L
TB1800L
TB2300L
TB2600L
TB3100L
TB3500L
58
65
75
90
120
140
160
190
220
275
320
5
5
5
5
5
5
5
5
5
5
5
77
88
98
130
160
180
220
265
300
350
400
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
50
50
50
50
50
50
50
50
50
50
50
800
800
800
800
800
800
800
800
800
800
800
150
150
150
150
150
150
150
150
150
150
150
800
800
800
800
800
800
800
800
800
800
800
100
100
100
60
60
60
60
40
40
40
40
SYMBOL
V
DRM
I
DRM
V
BR
I
BR
V
BO
I
BO
I
H
V
T
I
PP
C
O
PARAMETER
Stand-off Voltage
Leakage current at stand-off voltage
Breakdown voltage
Breakdown current
I
BR
Breakover voltage
Breakover current
I
BO
I
H
I
DRM
I
PP
I
V
V
T
V
BR
V
DRM
V
BO
Holding current
On state voltage
Peak pulse current
Off state capacitance
Note: 1
Note: 2
REV. 0, 15-Nov-2001, KSWB05
NOTES: 1. I
H
> (V
L
/R
L
) If this criterion is not obeyed, the T
SPD
Triggers but does not return correctly to high-resistance state.
The Surge recovery time does not exceed 30ms.
2. Off-state capacitance measured at f=1.0MHz; 1.0V
RMS
signal; VR=2V
DC
bias.