TABLE 1
Output Operation Time as a Function of Time Out Input Control Voltage
Input Voltage
V
IN
= 0
V
IN
= 0.25V
REG
V
IN
= 0.5V
REG
V
IN
= 0.75V
REG
*V
IN =
V
REG
60Hz Operation
5
10
20
30
30
50Hz Operation
6
12
24
36
36
Units
Minutes
Minutes
Minutes
Minutes
Seconds
.
*Walking Test:
Ambient light will not prevent motion from turning
the lights on or resetting the time-out counter
PIN ASSIGNMENT - TOP VIEW
DIFF. AMP. 1 OUTPUT
DIFF. AMP. 2 INPUT
(- )
DIFF. AMP. 2 OUTPUT
V
SS
AC
LR1
LR2
V
DD
1
2
3
16
15
14
DIFF. AMP 1 INPUT
(- )
DIFF. AMP 1 INPUT
(+)
5V REGULATOR OUTPUT
TIME-OUT INPUT
ON/OFF
LDR INPUT
MODE INPUT
LED OUTPUT
LSI
LS6506R
4
5
6
7
8
13
12
11
10
9
FIGURE 1A
PIN ASSIGNMENT - TOP VIEW
DIFF. AMP. 1 OUTPUT
DIFF. AMP. 2 INPUT
(- )
DIFF. AMP. 2 OUTPUT
V
SS
AC
N/C
TRIAC OUTPUT
V
DD
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
DIFF. AMP 1 INPUT
(- )
DIFF. AMP 1 INPUT
(+)
5V REGULATOR OUTPUT
TIME-OUT INPUT
ON / OFF
LDR INPUT
MODE INPUT
LED OUTPUT
LSI
FIGURE 1B
LS6507R
6506R-042308-3