欢迎访问ic37.com |
会员登录 免费注册
发布采购

LS7030 参数 Datasheet PDF下载

LS7030图片预览
型号: LS7030
PDF下载: 下载PDF文件 查看货源
内容描述: 8 DECADE复用COUNTER [8 DECADE MULTIPLEXED COUNTER]
分类和应用: 逻辑集成电路光电二极管驱动计算机
文件页数/大小: 4 页 / 50 K
品牌: LSI [ LSI COMPUTER SYSTEMS ]
 浏览型号LS7030的Datasheet PDF文件第2页浏览型号LS7030的Datasheet PDF文件第3页浏览型号LS7030的Datasheet PDF文件第4页  
LSI/CSI
UL
®
LS7030
(631) 271-0400 FAX (631) 271-0405
December 2002
LSI Computer Systems, Inc. 1235 Walt Whitman Road, Melville, NY 11747
A3800
8 DECADE MULTIPLEXED COUNTER
FEATURES:
• DC to 7.5 MHz Count Frequency
• Multiplexed BCD and 7 Segment Outputs
• DC to 500 kHz Scan Frequency
• +4.75V to +15V Operation (V
DD
-V
SS
)
• Compatible with CMOS Logic
• High Input Noise Immunity
• Counter Output Latches
• Leading Zero Blanking
• Low Power Dissipation
• All inputs protected
• 40 Pin DIP- See Figure 1
DESCRIPTION:
The LS7030 is a monolithic, ion implanted MOS Silicon Gate, 8
decade up counter. The circuit includes latches, multiplexer,
leading zero blanking and 7 segment data outputs.
8 DECADE UP COUNTER
The eight decade ripple through counter increments on the neg-
ative edge of the input count pulse. Maximum ripple time is 12µs
(99999999 to 00000000). Maximum count frequency is 7.5MHz.
RESET
All decades are reset to zero when Reset input is brought low for
a minimum of 4µs. The Overflow flip-flop is reset at the same
time. Reset must be high for a minimum of 1µs before next valid
count can be recorded.
LATCHES
Contents of counter are transferred to latches when LOAD signal
is brought low for a minimum of 4µs and kept low until a minimum
of 12µs has elapsed from previous negative edge of count pulse
(ripple time). Storage of valid data occurs when LOAD signal is
high for a minimum of 1µs before next negative edge of count
pulse or reset. Data is transferred for Overflow flip-flop to Over-
flow latch at the same time.
SCAN OSCILLATOR AND COUNTER
The scan counter is driven by an internal oscillator whose fre-
quency is determined by a capacitor connected between Os-
cillator input and Scan input. An external scan clock applied to
Scan input can also drive the scan counter. Scan counter ad-
vances on negative edge of scan clock.
The counter scans from MSD to LSD. When Scan Reset input is
brought high the scan counter is forced to MSD state. Internal
synchonization guarantees proper scanning no matter when Scan
Reset is brought low relative to scan clock. Maximum scan
frequency is 500kHz.
DECIMAL POINT
A high at the Decimal Point input resets the Blanking flip-flop
causing the display to unblank. Decimal Point should be brought
high at start of digit time which has active Decimal Point.
7030-121102-1
CONNECTION DIAGRAM - TOP VIEW
SCAN RESET INPUT
MSD STROBE 8
STROBE 7
STROBE 6
DIGIT
STROBE
OUTPUTS
STROBE 5
STROBE 4
STROBE 3
STROBE 2
LSD STROBE 1
DECIMAL POINT INPUT
BLANK OUTPUT
OVERFLOW OUTPUT
OVERFLOW INPUT
DECADE 6 OUTPUT,
DECADE 7 OUTPUT,
DECADE 6 OUTPUT,
D8
D7
D6
B8
BCD
DATA
OUTPUTS
B4
B2
B1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
LS7030
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
OSC. INPUT
SCAN INPUT
LAMP TEST INPUT
a
b
N.C.
c
d
COUNT INPUT
e
f
g
TEST COUNT INPUT, DIGITS 3 - 8
V
SS
V
GG
N.C.
N.C.
V
DD
RESET COUNTER INPUT
LOAD LATCH INPUT
SEGMENT
OUTPUTS
SEGMENT
OUTPUTS
DIGIT STROBES
Timing of Digit Strobes is arranged such that both edges of strobe
are guardbanded by a minimum 400ns within valid BCD data when
scan frequency is 100kHz or less. The guardband is a minimum of
200ns at 250kHz scan frequency. At 500kHz only negative edge of
Strobe is guaranteed to be within valid BCD data by a minimum
200ns.
OVERFLOW
The Overflow flip-flop sets on the first negative transition of the Over-
flow Input and remains set until Reset is brought low. Data is trans-
ferred from Overflow flip-flop to Overflow Latch when Load is brought
low. A high at the Overflow Latch causes display to unblank. Over-
flow Output is output of Overflow Latch. MSB outputs of Decades
6, 7, 8 are available for use as Overflow Input.
BLANKING
Leading zero blanking is employed. At start of each MSD to LSD
scan, display is blanked until a nonzero digit or active decimal point is
encountered. Displaly unblanks during LSD time and for a whole
scan when Overflow output is high. When Scan Reset is applied, dis-
play blanks to prevent display damage.
Blanking information is available at Blank output and is incorporated
into 7 segment information.
LSI
FIGURE 1