欢迎访问ic37.com |
会员登录 免费注册
发布采购

LS7313 参数 Datasheet PDF下载

LS7313图片预览
型号: LS7313
PDF下载: 下载PDF文件 查看货源
内容描述: AC电源控制器 [AC POWER CONTROLLERS]
分类和应用: 功率控制控制器
文件页数/大小: 4 页 / 45 K
品牌: LSI [ LSI COMPUTER SYSTEMS ]
 浏览型号LS7313的Datasheet PDF文件第2页浏览型号LS7313的Datasheet PDF文件第3页浏览型号LS7313的Datasheet PDF文件第4页  
UL
®
LSI/CSI
LS7310-7313
(631) 271-0400 FAX (631) 271-0405
LSI Computer Systems, Inc. 1235 Walt Whitman Road, Melville, NY 11747
A3800
AC POWER CONTROLLERS
FEATURES:
10 I/Os to Select/Indicate up to ten Power Levels
Inputs activated by Touch or Pushbutton Switch
Output switches pure and precise AC Power to Load
Operates with 50Hz/60Hz line frequency
Rugged, latchup-free process technology
+10V to +14V operation (Vss-V
DD
)
LS7310 thru LS7313 (DIP);
LS7310-S thru LS7313-S (SOIC) - See Figure 1
APPLICATIONS:
Universal and shaded-pole motor speed control for modern
appliance designs. Eliminates awkward mechanical switch
assemblies and multi-tapped motor windings.
DESCRIPTION:
The LS7310-LS7313 are MOS integrated circuits specifically
designed for motor speed control applications in appliances
such as blenders, etc. I/Os (PLs) are provided for selecting/
indicating from one to ten power levels. The LS7310 and 7311
are designed for pushbutton control. The LS7312 and LS7313
are designed for touch control. (See Fig.4A and 4B)
INPUT/OUTPUT DESCRIPTION:
PL1-PL10 (Pins 1-9, 18)
Ten inputs/outputs for selecting ten output phase angles (pow-
er levels). When no power level is selected (such as after sys-
tem power-up), PL1-PL10 all act as inputs. When a power level
is selected by applying a logic zero at one of these inputs for
T
H
time (See Dynamic Characteristics), the selected input
switches status to become an output in order to drive a display,
such as an LED. It switches back to the input state only when
another PL input is activated. (See Note 1)
CONNECTION DIAGRAM - TOP VIEW
PL2
PL3
PL4
PL5
PL6
PL7
PL8
PL9
PL10
1
2
3
4
5
6
7
8
9
LS7310
January 1997
18 PL1
17 TRIG
16 Vss (+V)
15 SYNC
14 CAP
13 RUN
12 P U L S E
11 OFF
10 V
DD
(-V)
PULSE (Pin 12)
A logic 0 applied to this input turns the TRIG output on for
as long as the PULSE input is maintained. The PULSE input
however, has no effect if no power level is in selection or if
the TRIG output has already been turned on by means of
the RUN input. (See Note 1)
SYNC (Pin 15)
Input for PLL reference frequency (50Hz/60Hz). All internal
clock frequencies are synchronized with the SYNC input.
CAP (Pin 14)
Input for component connection for the PLL filter capacitor.
TRIG (Pin 17)
This output is designed to drive a triac in series with the
load and control its firing angle with respect to the AC line.
The LS7310 and LS7312 provide a nominal 33µs output
pulse width. Since some motors have large inductive loads
producing a large phase delay between voltage and current,
a wider output pulse may be required. The LS7311 and
LS7313 produce a 1ms output pulse width. Otherwise,
these parts are identical to the LS7310 and LS7312,
respectively.
RUN (Pin 13)
When a logic 0 is applied to the RUN input for T
H
time, the out-
put (TRIG) is turned on at a phase angle selected earlier by
one of the PL I/Os. If no power level was selected prior to the
application of the RUN input, the circuit remains unaffected.
Note that once the TRIG output has been enabled, its phase
angle can be altered by applying any other PL input without the
Vss (Pin 16)
need to apply the RUN input again. (See Note 1)
Supply voltage positive terminal.
OFF (Pin 11)
When a logic 0 is applied to this input for T
H
time, TRIG output
is turned off, if it was on. If TRIG was already off, the circuit re-
mains unaffected. Note that OFF input does not alter the power
level selected by a PL input. Following an OFF operation,
TRIG can be turned on at the previous phase angle by applying
the RUN input. (See Note 1)
7310-011697-1
V
DD
(Pin 10)
Supply voltage negative terminal (ground).
NOTE 1:
LS7310, LS7311 have an internal pullup resistor on this
input and LS7312, LS7313 do not. (See DC Electrical Character-
istics.)
LSI
FIGURE 1