General Information
Product Nomenclature
LUXEON T emitters are specified and binned “hot” under conditions comparable to those found in “real-world” lighting
products. The test conditions for LUXEON T are 700 mA DC with junction temperature at 85°C.
The part number designation is explained as follows:
L X H c - F W x x - Y and L X H c - F W x x - A B C D
Where:
c – designates minimum CRI performance (7 for 70 CRI, 8 for 80 CRI, 9 for 90 CRI, 1 for Royal Blue)
xx – designates nominal ANSI CCT (27 for 2700K, 30 for 3000K, RB for Royal Blue)
Y – 3 designates 3 SDCM and 5 designates 5 SDCM
ABCD – minimum flux output/ radiometric power (mW)
Therefore, 3-Step 80 CRI products tested and binned at 2700K will have the following part number:
L X H 8 – FW 2 7 - 3
Therefore, 1000 mW Royal Blue products will have the following part number:
LXH1 - FWRB - 1000
Lumen Maintenance
LUXEON T products are tested in compliance with LM-80. Please visit
www .philipslumileds .com/support/documentation/
lumen-maintenance
or contact your local Philips Lumileds Technical Solutions Manager for TM-21 extrapolations or
other support.
Environmental Compliance
Philips Lumileds is committed to providing environmentally friendly products to the solid-state lighting market. LUXEON T
is compliant to the European Union directives on the restriction of hazardous substances in electronic equipment, namely the
RoHS and REACH directives. Philips Lumileds will not intentionally add the following restricted material to the LUXEON T:
lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB) or polybrominated diphenyl ethers (PBDE).
DS106 LUXEON T 20130630 ©2013 Philips Lumileds Lighting Company.