欢迎访问ic37.com |
会员登录 免费注册
发布采购

LXHL-MMJA 参数 Datasheet PDF下载

LXHL-MMJA图片预览
型号: LXHL-MMJA
PDF下载: 下载PDF文件 查看货源
内容描述: 功率光源丽讯洪水 [power light source Luxeon Flood]
分类和应用:
文件页数/大小: 8 页 / 215 K
品牌: LUMILEDS [ LUMILEDS LIGHTING COMPANY ]
 浏览型号LXHL-MMJA的Datasheet PDF文件第1页浏览型号LXHL-MMJA的Datasheet PDF文件第2页浏览型号LXHL-MMJA的Datasheet PDF文件第3页浏览型号LXHL-MMJA的Datasheet PDF文件第5页浏览型号LXHL-MMJA的Datasheet PDF文件第6页浏览型号LXHL-MMJA的Datasheet PDF文件第7页浏览型号LXHL-MMJA的Datasheet PDF文件第8页  
Electrical Characteristics at Junction
Temperature, T
J
= 25
o
C
Notes:
Flood 12-Up
Temp
coefficient
1.
Thermal
junction
to board
[3]
(
o
C/W) Rθ
J-B
resistance,
Radiation
Pattern
Color
Forward Voltage
(V) V
F
Min.
Typ.
Max.
resistance
[1]
Dynamic
(Ω) R
D
of
Forward
voltage
[2]
(mV/
o
C)
∆V
F
/
∆T
J
test
current
(mA) I
F
2.
Batwing
(low dome)
White
Green
Cyan
Blue
Red
Amber
16
16
16
16
14
14
14
14
21
21
21
21
17
17
18
18
24
24
24
24
20
20
21
21
3
3
3
3
7.2
7.2
7.2
7.2
-12
-12
-12
-12
-12
-12
-12
-12
1.7
1.7
1.7
1.7
1.7
1.7
1.9
1.9
700
700
700
700
700
700
700
700
3.
Lambertian
Red
(high dome)
Amber
Dynamic resistance is the inverse of
the slope in linear forward voltage
model for LEDs. See
Figures 3a and
3b.
Measured between 25
o
CT
T
J
110
o
C at I
F
= 700mA for Flood 12-Up
and I
F
= 1050mA for Flood 18-Up.
To determine the junction
temperature, multiply by total array
power. Due to the high packing
density of the Floods, the board
temperature rise is significant and
must always have additional heat
sinking at nominal operating
conditions.
Flood 18-Up
Dynamic
resistance
[1]
(Ω) R
D
Temp
coefficient
of forward
voltage
[2]
(mV/
o
C)
∆V
F
/
∆T
J
Thermal
resistance,
junction
to board
[3]
(
o
C/W) Rθ
J-B
test
current
(mA) I
F
Radiation
Pattern
Color
Forward Voltage
(V) V
F
Min.
Typ.
Max.
Batwing
(low dome)
White
Green
Cyan
Blue
Red
Amber
16
16
16
16
14
14
14
14
21
21
21
21
17
17
18
18
24
24
24
24
20
20
21
21
2
2
2
2
4.8
4.8
4.8
4.8
-12
-12
-12
-12
-12
-12
-12
-12
1.1
1.1
1.1
1.1
1.1
1.1
1.3
1.3
1050
1050
1050
1050
1050
1050
1050
1050
Lambertian
Red
(high dome)
Amber
Absolute Maximum Ratings
Flood 12-Up
Parameter
White/Green/
Cyan/Blue
Red/Amber
Flood 18-Up
White/Green/
Cyan/Blue
Red/Amber
Notes:
1.
Proper current derating must be
observed to maintain junction
temperature below the maximum.
For more information, consult Luxeon
Design Guide, available upon request.
LEDs are not designed to be driven in
reverse bias. Please consult Lumileds’
Application Brief AB11 for further
information.
DC Forward Current (mA)
[1]
Peak Pulsed Forward Current (mA)
Average Forward Current (mA)
ESD Sensitivity
[2]
LED Junction Temperature (
o
C)
Aluminum-Core PCB Temperature (
o
C)
Storage & Operating Temperature(
o
C)
700
770
1000
1100
700
700
±
16,000V HBM
135
120
105
105
-40 to +105
-40 to +105
1050
1155
1500
1650
1050
1050
±
16,000V HBM
135
120
105
105
-40 to +105
-40 to +105
2.
Luxeon Flood
4