Product Selection
Product Selection Guide for LUXEON M 12V White
Junction Temperature = 85°C
Table 1.
Performance at Test Current
Nominal
CCT
3000K
4000K
5000K
5700K
6500K
2700K
3000K
3500K
4000K
5000K
2700K
3000K
Notes for Table 1:
1. Philips Lumileds maintains a tolerance of ± 6.5% on flux measurements.
2. Test current is 700 mA for all LXRx-SWxx products.
Part
Number
LXR7-SW30
LXR7-SW40
LXR7-SW50
LXR7-SW57
LXR7-SW65
LXR8-SW27
LXR8-SW30
LXR8-SW35
LXR8-SW40
LXR8-SW50
LXR9-SW27
LXR9-SW30
Minimum
CRI
70
70
70
70
70
80
80
80
80
80
90
90
Minimum Luminous
Flux (lm)
840
900
900
900
900
680
710
745
780
800
570
580
Typical Luminous
Flux (lm)
905
980
980
1000
1000
760
800
860
905
905
610
620
Product Selection Guide for LUXEON M 12V Royal Blue
Junction Temperature = 85°C
Table 2.
Performance at Test Current
Color
Royal Blue
Note for Table 2:
1. Philips Lumileds maintains a tolerance of ± 6.5% on flux measurements.
2. Test current is 700 mA for LXR0-SR00 products.
Part
Number
LXR0-SR00
Minimum
Radiometric Power (mW)
4000
Typical
Radiometric Power (mW)
4200
Typical Radiant
Efficacy (%)
53.6
LUXEON M Datasheet DS103 20130418 ©2013 Philips Lumileds Lighting Company.