欢迎访问ic37.com |
会员登录 免费注册
发布采购

AT-119TR-3000 参数 Datasheet PDF下载

AT-119TR-3000图片预览
型号: AT-119TR-3000
PDF下载: 下载PDF文件 查看货源
内容描述: 2.25伏电压可变衰减器吸收 - 40分贝, 1.8.2.5 GHz的 [2.25 Volt Voltage Variable Absorptive Attenuator - 40 dB, 1.8.2.5 GHz]
分类和应用: 衰减器
文件页数/大小: 4 页 / 138 K
品牌: MA-COM [ M/A-COM TECHNOLOGY SOLUTIONS, INC. ]
 浏览型号AT-119TR-3000的Datasheet PDF文件第2页浏览型号AT-119TR-3000的Datasheet PDF文件第3页浏览型号AT-119TR-3000的Datasheet PDF文件第4页  
2.25 Volt Voltage Variable Absorptive
Attenuator - 40 dB, 1.8—2.5 GHz
AT-119
Features
Functional Schematic
V
CC
5
V
CTL
4
Single Positive Voltage Control 0 to +2.25 Volts
>50 dB Attenuation Range at 2.1 GHz
Low DC Power Consumption
Low Cost SOT-25 Plastic Package
Tape and Reel Packaging Available
Description
M/A-COM’s AT-119 is a GaAs MMIC voltage variable
absorptive attenuator in a low cost, SOT-25 five-lead,
surface mount plastic package. M/A-COM fabricates the
AT-119 with a proven monolithic GaAs self-aligned gate
process that features full chip passivation for performance
and reliability
1
RF
100 pF
2
GND
3
100 pF
RF
Applications
The AT-119 is ideally suited for applications that require
fine tuning, linear attenuation with voltage, and very low
power consumption.
Typical applications for the AT-119 include automatic gain
control circuits in satellite radio receivers and other wireless
receivers.
1. V
CC
= +3.3 V
DC
@ 50 µA max.
2. V
CTL
= 0 V
DC
to +3.3 VDC @ 50 µA max.
3. External DC blocking capacitors are required on all RF
ports.
Absolute Maximum Ratings
1
@ T
A
= +25 °C (unless otherwise specified)
Parameter
Maximum Input Power
Supply Voltage V
CC
ControlVoltage V
CTL
Operating Temperature
Storage Temperature
Absolute Maximum
+21 dBm
-1 V, + 8 V
-1 V, V
CC
+0.5 V
-40°C to +85°C
-65°C to +150°C
1. Exceeding any one or a combination of these limits may
cause permanent damage.
Electrical Specifications @ T
A
= +25 °C, Frequency = 2.4 GHz, V
CC
= 3.3 V
DC1
Parameters
Test Conditions
Units
Min
Typ
Max
Minimum Insertions Loss
Maximum Attenuation
Attenuation Slope
Return Loss
Input Power for 1 dB Change in Attenua-
tion
Input 3
rd
Order Intercept Point
Switching Speed
Transients
V
CTL
= 2.25 V
DC
V
CTL
= 0.5 V
DC
0.75 V
DC
< V
CTL
< 1.75 V
DC
0.6 V
DC
< V
CTL
< 1.75 V
DC
0 V
DC
< V
CTL
< 3.0 V
DC
0 V
DC
< V
CTL
< 3.0 V
DC
50% V
CTL
to 10% / 90% RF
V
CTL
= 3 V
DC,
In-Band
dB
dB
dB/V
dB
dBm
dBm
nSec
mV
37
24
3.0
3.2
>12
>10
>20
180
10
1. All measurements in a 50-τ system unless otherwise specified. The RF ports must be blocked outside of the package from
ground or any other voltage.