欢迎访问ic37.com |
会员登录 免费注册
发布采购

PESD0402-140 参数 Datasheet PDF下载

PESD0402-140图片预览
型号: PESD0402-140
PDF下载: 下载PDF文件 查看货源
内容描述: ESD保护器件 [ESD Protection Devices]
分类和应用: 电阻器
文件页数/大小: 6 页 / 270 K
品牌: MA-COM [ M/A-COM TECHNOLOGY SOLUTIONS, INC. ]
 浏览型号PESD0402-140的Datasheet PDF文件第1页浏览型号PESD0402-140的Datasheet PDF文件第2页浏览型号PESD0402-140的Datasheet PDF文件第3页浏览型号PESD0402-140的Datasheet PDF文件第4页浏览型号PESD0402-140的Datasheet PDF文件第5页  
Parameter Definitions for ESD Devices
Operation Voltage (V
DC
)
Defined as DC voltage, under which device is in OFF state and leakage current below certain threshold.
Leakage Current (I
L
)
Current through device under Operation Voltage V
DC
.
Trigger Voltage (V
T
)
Voltage at which the device switches from the OFF to the ON state, during the IEC waveform or the TLP system.
Clamping Voltage (V
C
)
Voltage cross device under 8 kV per IEC or measured by TLP system. Typically measured 30 ns after initiation of the ESD pulse
(for TLP both 30ns and 60ns are sometimes used).
,
Capacitance (C
P
)
Capacitance of the device measured at 1 MHz with 0V and max operating voltage bias.
Part Numbering System for ESD Devices
PESD xxxx Q - 240
Operating Voltage Designator 24 x 10˚ = 24V
DC
7
Array of 4 Elements
EIA Size
Series
Warning :
Application Limitations for PESD0402-140, PESD0603-240 and PESD1206Q-240: These parts are not intended to be used under power
bus applications. Users should independently evaluate the suitability of and test each product selected for their own application.
All information, including illustrations, is believed to be accurate and reliable. Users, however, should independently evaluate the suitability of
and test each product selected for their application. Tyco Electronics Corporation makes no warranties as to the accuracy or completeness of
the information, and disclaims any liability regarding its use. Tyco Electronics only obligations are those in the Tyco Electronics Standard Terms
and Conditions of Sale and in no case will Tyco Electronics be liable for any incidental, indirect, or consequential damages arising from the sale,
resale, use, or misuse of its products. Specifications are subject to change without notice. In addition, Tyco Electronics reserves the right to make
changes to materials or processing that do not affect compliance with any applicable specification without notification to Buyer. Without
expressed or written consent by an officer of Tyco Electronics, Tyco Electronics does not authorize the use of any of its products as components
in nuclear facility applications, aerospace, or in critical life support devices or systems.
50
RoHS Compliant, ELV Compliant
HF
Halogen Free