General Purpose Relays  
SCHRACK  
Power PCB Relay RT1 (Continued)  
Coil versions, DC-coil  
Coil  
Rated  
voltage  
VDC  
5
Operate  
voltage  
VDC  
3.5  
Release  
voltage  
VDC  
0.5  
Coil  
resistance  
Ohm  
62+10%  
90+10%  
200+10%  
360+10%  
1440+10%  
5520+10%  
8570+12%  
28800+12%  
Rated coil  
power  
mW  
code  
005  
006  
009  
012  
024  
048  
060  
110  
403  
6
9
4.2  
0.6  
400  
6.3  
8.4  
16.8  
33.6  
42.0  
77.0  
0.9  
400  
12  
1.2  
400  
24  
2.4  
400  
48  
4.8  
417  
60  
6.0  
420  
110  
11.0  
420  
All figures are given for coil without preenergization, at ambient temperature +23°C  
Other coil voltages on request  
Coil versions, AC-coil 50Hz  
Coil  
Rated  
Operate  
voltage  
50 Hz  
VAC  
Release  
voltage  
50 Hz  
VAC  
Coil  
Rated coil  
power  
50 Hz  
VA  
code  
voltage  
resistance  
VAC  
24  
115  
120  
200  
230  
Ohm  
524  
615  
620  
700  
730  
18.0  
3.6  
350+10%  
8100+15%  
8800+15%  
24350+15%  
32500+15%  
0.76  
86.3  
17.3  
0.76  
90.0  
18.0  
0.75  
150.0  
172.5  
30.0  
0.76  
34.5  
0.74  
All figures are given for coil without preenergization, at ambient temperature +23°C  
Insulation  
Dielectric strength coil-contact circuit  
open contact circuit  
5000 Vrms  
1000 Vrms  
W 10 / 10 mm  
W IIIa  
Clearance / creepage coil-contact circuit  
Material group of insulation parts  
Tracking index of relay base  
Insulation to IEC 60664-1  
Type of insulation coil-contact circuit  
open contact circuit  
PTI 250 V  
reinforced  
functional  
250 V  
Rated insulation voltage  
Pollution degree 12 A version  
16 A version  
3
3
3
2
Rated voltage system  
240 V  
400 V  
Overvoltage category  
III  
Other data  
RoHS - Directive 2002/95/EC  
Flammability class according to UL94  
compliant as per product date code 0413  
V-0  
For WG version: GWFI to IEC 60335-1 (IEC 60695-2-12)  
GWIT to IEC 60335-1 (IEC 60695-2-13)  
Ambient temperature range DC coil  
AC coil  
> 850 °C  
> 755 °C  
-40...+85°C  
-40...+70°C  
typ 7 / 3 ms  
typ 1 / 3 ms  
20 / 5 g, 30 ... 500 Hz  
100 g  
Operate- / release time DC coil  
Bounce time DC coil, NO / NC contact  
Vibration resistance (function), NO / NC contact  
Shock resistance (destruction)  
Category of protection  
Mounting  
RTII - flux proof, RTIII - wash tight  
pcb or on socket  
any  
Mounting position  
Mounting distance DC / AC coils  
Resistance to soldering heat flux-proof version  
wash-tight version  
0 / 2.5 mm  
270°C / 10 s  
260°C / 5 s  
14 g  
Relay weight  
Packaging unit  
20 / 500 pcs  
Accessories  
For details see datasheet  
Accessories Power Relay RT  
2
Datasheet  
Rev. HC1  
Dimensions are in mm unless  
Product specification  
processing information  
only to be used together  
with the 'Definitions' at  
schrackrelays.com in the  
‘Schrack’ section.  
Issued 2008/03  
otherwise specified and are  
shown for reference purposes  
only.  
according to IEC 61810-1.  
Product data, technical para-  
meters, test conditions and  
www.tycoelectronics.com  
www.schrackrelays.com  
Specifications subject to  
change.