欢迎访问ic37.com |
会员登录 免费注册
发布采购

1-6609113-3 参数 Datasheet PDF下载

1-6609113-3图片预览
型号: 1-6609113-3
PDF下载: 下载PDF文件 查看货源
内容描述: 开关符合IEC连接器体积小巧 [Switch with IEC Connector Compact Size]
分类和应用: 开关连接器
文件页数/大小: 2 页 / 89 K
品牌: MACOM [ Tyco Electronics ]
 浏览型号1-6609113-3的Datasheet PDF文件第2页  
CORCOM Product Guide
Switch with IEC Connector Compact Size
C Series
UL Recognized
CSA Certified
VDE Approved
CFS
CS
Applies to Filtered models only.
C Series
Two function power entry module combining a DPST switch
and an IEC 320 power line connector. Compact packaging
allows a smaller panel cutout with choice of snap-in or
flange mounting. Available with general purpose filtering (F
models - CFS, CFE), medical application filtering (H models
- CHS, CHE) or unfiltered (CS, CE). Terminals allow for easy
connection to any wiring scheme. Preconnected terminals
from line to switch are available (B Models - CBS, CBE) for
reducing OEM wiring time.
The medical versions (H models) are designed specifically
for health care applications. Their extremely low leakage
current allows compliance with UL544 and UL2601 as well
as CSA22.2 health care specifications for use with both
patient and non-patient care equipment. For more
information on UL544 or UL2601, see Appendix C.
Note: When using the models with an IEC connector,
remember that the leakage current of the companion line
cord, GA400, is more significant than that of the filter -
which may disqualify this line cord from use in patient care
applications.
Specifications
Maximum leakage current, each line to ground: †
F Models
H Models
@120 VAC 60 Hz:
.25 mA
2 µA
@250 VAC 50 Hz:
.40 mA
5 µA
Hipot rating (one minute):
line-to-ground
2250 VDC
line-to-line
1450 VDC
Operating frequency:
50/60 Hz
Rated voltage:
Operating voltages:
Switch:
250 VAC
115/230 VAC
Double-insulated rated
for 10,000 operations
at full load.
51 Amp inrush capability.
18 lb/80 N
Unfiltered Push-on Force:
Electrical Schematics
F Models (CFS, CFE)
LINE
LOAD
H Models (CHS, CHE)
LINE
LOAD
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
Current
Frequency MHz
Rating
0.05 0.15 0.5
1
5
F Models
0
1A
10
26
46
48
46
0
3A
8
16
32
36
43
0
6A
4
11
22
27
36
10A
1
4
14
18
27
H Models
0
1A
16
21
37
44
26
14
31
32
26
9
0
3A
0
6A
4
10
22
23
19
10A
2
6
10
15
11
Line-to-line in 50 ohm circuit
Current
Frequency MHz
Rating
0.05 0.15 0.5
1
5
F Models
0
1A
1
3
13
28
62
0
3A
2
6
14
23
65
0
6A
2
6
14
27
46
10A
1
7
14
23
42
H Models
0
1A
1
6
13
29
38
0
3A
1
5
10
22
36
0
6A
1
5
14
20
31
10A
1
4
11
19
32
10
47
48
41
33
21
24
18
11
30
46
50
50
42
10
14
13
9
10
67
65
48
44
42
34
33
37
30
42
67
58
62
26
36
37
38
B Models (CBS, CBE)
Power On/Off
L
G
L
Note 1
Note 1
Note 2
G
Note 2
N
N
Note 1: Jumpers provided on CBS and CBE versions only.
Note 2: Location of optional filter
Resistor location for reference only.
110
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com