欢迎访问ic37.com |
会员登录 免费注册
发布采购

R10S-R2W1DC 参数 Datasheet PDF下载

R10S-R2W1DC图片预览
型号: R10S-R2W1DC
PDF下载: 下载PDF文件 查看货源
内容描述: 通用继电器工业继电器 [General Purpose Relays Industrial Relays]
分类和应用: 继电器
文件页数/大小: 6 页 / 762 K
品牌: MACOM [ Tyco Electronics ]
 浏览型号R10S-R2W1DC的Datasheet PDF文件第1页浏览型号R10S-R2W1DC的Datasheet PDF文件第2页浏览型号R10S-R2W1DC的Datasheet PDF文件第4页浏览型号R10S-R2W1DC的Datasheet PDF文件第5页浏览型号R10S-R2W1DC的Datasheet PDF文件第6页  
General Purpose Relays  
Industrial Relays  
Potter & Brumfield  
R10 Series Panel Plug-in Relay (Continued)  
Coil versions, DC coil (continued)  
Operative Range  
R10 Relays (DC Only) Typical Ranges of Operations @ 25°C  
Coil  
code  
Maximum  
coil current  
mADC  
Operate  
current  
mADC  
Coil  
resistance  
Ω 10ꢀ  
Pick-up  
coil power  
mW  
(Curves for reference only. If specific  
J - sensitive DC current adjustment – R10S types only  
values are required, testing is required.)  
2 pole  
30  
25  
12  
10  
1)  
J500  
J1.0K  
J2.5K  
J5.0K  
J10.0K  
J16.0K  
J30.0K  
4 pole  
J500  
J1.0K  
J2.5K  
J5.0K  
J10.0K  
J16.0K  
J30.0K  
6.3  
4.5  
2.9  
2
1.4  
1.2  
0.8  
500  
1000  
2500  
5000  
10000  
16000  
30000  
20  
20  
25  
20  
20  
25  
20  
Typical Operate  
and Release Time  
2)  
(all contact configurations)  
8
6
4
2
20  
15  
10  
5
3)  
Release Time  
(no suppression)  
9
500  
1000  
2500  
5000  
10000  
16000  
30000  
45  
45  
45  
45  
40  
35  
45  
6.5  
4.1  
2.9  
2
1.4  
1.2  
2)  
3)  
Operate Time  
1.0  
1.33 1.5  
2.0  
2.5  
3.0  
Multiple of Max. Pull-in Voltage or Current  
1) Suggested for 5VDC operation  
2) Suggested for 12VDC operation  
3) Suggested for 24VDC operation  
R10 Ultra-Sensitive “SS” and “JJ” Typical Ranges of Operation @ 25°C  
JJ - ultrasensitive DC current adjustment  
1 pole  
(Curves for reference only. If specific  
values are required, testing is required.)  
10  
8
50  
JJ1.0K  
JJ2.5K  
JJ5.0K  
JJ10.0K  
JJ15.0K  
JJ30.0K  
2 pole  
JJ1.0K  
JJ2.5K  
JJ5.0K  
JJ10.0K  
JJ15.0K  
JJ30.0K  
4 pole  
45  
28  
20  
14  
11.5  
8.3  
4.5  
2.9  
2.1  
1.5  
1.2  
0.85  
1000  
2500  
5000  
10000  
15000  
30000  
20  
25  
25  
25  
25  
25  
Typical Operate  
and Release Time  
(all contact configurations)  
40  
30  
6
Release Time  
(no suppression)  
45  
28  
20  
14  
11.5  
8.3  
6.5  
4.1  
2.9  
2
1.7  
1.2  
1000  
2500  
5000  
10000  
15000  
30000  
45  
45  
45  
40  
45  
45  
20  
10  
4
2
Operate Time  
3.0  
4.0  
1.0  
1.5 2.0  
JJ1.0K  
JJ2.5K  
JJ5.0K  
JJ10.0K  
JJ15.0K  
JJ30.0K  
45  
28  
20  
14  
11.5  
8.3  
9
1000  
2500  
5000  
10000  
15000  
30000  
85  
85  
85  
90  
85  
90  
Multiple of Max. Pull-in Voltage or Current  
5.8  
4.1  
3
2.4  
1.7  
Typical Coil Inductance  
500  
All figures are given for coil without preenergization, at ambient temperature +23°C.  
100  
50  
Coil versions, AC coil (dual coil diode rectified construction)  
Coil  
Rated  
voltage  
VAC  
Operate  
voltage  
VAC  
Coil  
resistance  
Ω 20ꢀ  
code  
10  
Armature (open)  
Armature (closed)  
Standard AC  
2 and 4 pole  
6V  
12V  
24V  
48V  
115V  
6 and 8 pole  
6V  
12V  
6
5
9
18  
36  
86  
25  
120  
500  
2000  
9000  
1.0  
0.5  
12  
24  
48  
115  
0.1  
10  
50 100  
500 1K  
Coil Resistance (Ohms)  
5K 10K  
100K  
6
5
9
18  
36  
86  
15  
90  
350  
1400  
7500  
12  
24  
48  
115  
24V  
48V  
115V  
All figures are given for coil without preenergization, at ambient temperature +23°C.  
3
08-2011, Rev. 0811  
Datasheets and product specification  
according to IEC 61810-1 and to be used  
only together with the ‘Definitions’ section.  
Datasheets and product data is subject to the  
terms of the disclaimer and all chapters of  
the ‘Definitions’ section, available at  
http://relays.te.com/definitions  
Datasheets, product data, ‘Definitions’ sec-  
tion, application notes and all specifications  
are subject to change.  
www.te.com  
© 2011 Tyco Electronics Corporation,  
a TE Connectivity Ltd. company