欢迎访问ic37.com |
会员登录 免费注册
发布采购

704-5120-540 参数 Datasheet PDF下载

704-5120-540图片预览
型号: 704-5120-540
PDF下载: 下载PDF文件 查看货源
内容描述: 地平线?模拟704导波雷达液位变送器 [Horizon? Model 704 Guided Wave Radar Level Transmitter]
分类和应用: 雷达
文件页数/大小: 12 页 / 474 K
品牌: MAGNETROL [ MAGNETROL INTERNATIONAL, INC. ]
 浏览型号704-5120-540的Datasheet PDF文件第2页浏览型号704-5120-540的Datasheet PDF文件第3页浏览型号704-5120-540的Datasheet PDF文件第4页浏览型号704-5120-540的Datasheet PDF文件第5页浏览型号704-5120-540的Datasheet PDF文件第7页浏览型号704-5120-540的Datasheet PDF文件第8页浏览型号704-5120-540的Datasheet PDF文件第9页浏览型号704-5120-540的Datasheet PDF文件第10页  
T W I N
R O D
P R O B E
7XB Twin Rod-Rigid
Recommended for
Not recommended for
Materials/Wetted parts
Optional
Process seal
Spacers
Diameter
Process connection thread
Flange ANSI (DIN)
Length
Transition zone

Top
Bottom
Deadband
Process temperature
Ž
Top
Maximum
General purpose, foam, minor film coating
Media bridging between rods
or building up on spacers
316L stainless steel, TFE, Viton
®
GFLT
Hastelloy C, Monel
Viton
®
GFLT O-ring
Œ
TFE
Two,
.50" (13 mm) rod;
.875" (22 mm) C
L
to C
L
2" NPT, 2" BSP
2" to 4" (DN50 to 100)
1" (25 mm) @
ε
r > 10, 8" (200 mm) @
ε
r < 10
(+4" (100 mm) inactive)
6" (150 mm) @
ε
r = 2.5
1" (25 mm) @
ε
r = 80
24 to 192 inches (60 to 488 cm)
4"(+4" inactive section)
+400° F @ 200 psig (+200° C @ 13 bar)
-40° F @ 750 psig (-40° C @ 50 bar)
750 psig @ +70° F (50 bar @ +20° C)
Yes, not hermetic
2.5
1500
Active rod > 1" from any obstruction
Film: 3% max. error of coated length with conductive media
Bridging not recommended
Yes
Yes
No
No
Minimum/cryogenic
Process pressure
Maximum
Minimum/vacuum service
Dielectric range
Maximum viscosity (cP)
Mounting effects

Coating/Buildup

Foam
Corrosives
Hygienic
Overfill
Approvals
FM
CSA
ATEX
OTHER
Yes
Yes
Yes
No

Transition Zone is dielectric dependent:
ε
r = dielectric permittivity.
Unit will function but accuracy will decrease in Transition Zone.
NOTE: Output may go to Fault mode when medium is within top 7 inches of probe and
ε
r <20.
Ž
Refer to Ambient Temperature vs. Process Temperature graph on page 8.

Bridging is defined as continuous accumulation of material between the probe elements.

Minimum stillwell diameter for Twin Rod probe is 3 inch (80 mm).
Œ
Refer to Selection Chart on page 7 for optional O-rings.