Eclipse
®
Enhanced Model 705
Guided Wave Radar
Level Transmitter
D E S C R I P T I O N
The Enhanced Eclipse Model 705 Transmitter is a loop-
powered, 24 VDC liquid-level transmitter based on the
revolutionary Guided Wave Radar (GWR) technology.
Encompassing a number of significant engineering
accomplishments, this leading-edge level transmitter is
designed to provide measurement performance well
beyond that of many traditional technologies, as well as
“through-air” radar.
The innovative enclosure is a first in the industry, orient-
ing dual compartments (wiring and electronics) in the
same plane, and angled to maximize ease of wiring, con-
figuration, and data display.
One universal transmitter can be used with all probe
types and offers enhanced reliability for use in SIL 2
hardware systems.
Eclipse supports the FDT/DTM standard and, with the
PACTware
™
Frame Program, allows for additional config-
uration and trending flexibility.
Measures Level, Volume, and Interface
SIL 2
F E A T U R E S
•
“T
RUE
L
EVEL
” measurement—not affected by media
characteristics (e.g., dielectrics, pressure, density, pH,
viscosity, etc.)
•
Two-wire, 24 VDC loop-powered transmitter for
level, interface, or volume.
•
20-point custom strapping table for volumetric
output.
•
360° rotatable housing can be dismantled without
depressurizing the vessel.
•
Two-line, 8-character LCD and 3-button keypad.
•
Probe designs: up to +800° F / 6250 psi (+430° C /
430 bar).
•
Saturated steam applications up to 2250 psi @
+650° F (155 bar @ +345° C).
•
Cryogenic applications down to -320° F (-196° C).
•
Integral or remote electronics (up to 12 feet (3.6 m)).
•
Suited for SIL 1 or SIL 2 Loops (full FMEDA report
available).
A P P L I C A T I O N S
MEDIA:
Liquids or slurries; hydrocarbons to water-based
media (dielectric 1.4 - 100).
VESSELS:
Most process or storage vessels up to rated
probe temperature and pressure.
CONDITIONS:
All level measurement and control appli-
cations including process conditions exhibiting visible
vapors, foam, surface agitation, bubbling or boiling, high
fill/empty rates, low level and varying dielectric media or
specific gravity.
Download your free copy of the Eclipse 705 performance
reports by WIB/Evaluation International (SIREP)/EXERA
from magnetrol.com.