Model R82
Pulse Burst Radar
Level Transmitter
D E S C R I P T I O N
The Model R82 is an economical, loop-powered radar
transmitter bringing radar to everyday applications. Daily
applications that have been considered for Ultrasonic can
now use radar technology with its superior performance.
The electronics are housed in a compact, single com-
partment cast aluminum or Lexan
®
housing. The R82
measures effectively even when atmospheres above the
liquid are saturated with vapor. Pulse Burst technology
and advanced signal processing manage common distur-
bances such as false echoes caused by obstructions,
multi-path reflections from tank sidewalls or turbulence
caused by agitators, aggressive chemicals, or aerators.
T E C H N O L O G Y
Model R82 Pulse Burst Radar emits short bursts of
26 GHz energy. High-speed timing circuitry measures the
time of the signal reflected off the liquid surface.
Sophisticated signal processing filters out false reflections
and other background noises. The exact level is then
calculated, by factoring tank height and sensor offset
information. The Model R82 circuitry is extremely energy
efficient so no duty cycling is needed like with likewise
radars. This allows tracking of high rates of level change
up to 180"/min (4.5m/min).
F E A T U R E S
26 GHz frequency
24 VDC, loop-power supply voltage
Configure with 2-line
×
16-character display, 4-push-
button keypad and PACTware
PC Program (see bul-
letin 59-101)
Range (from threads) of 15" to 40 feet (0.4 to 12.2 m)
Volume/Flow: 20-point strapping table
Ambient: -40° to +175° F (-40° to +80° C)
Process
Temperature:
Pressure:
Dielectric:
-40° to +200° F (-40° to +93° C)
Vacuum to 200 psig (13.8 bar)
1.7-100
A P P L I C A T I O N S
MEDIA:
Liquids and slurries; hydrocarbons to water
based media (dielectric 1.7–100)
VESSELS:
Most effective in storage vessels up to rated
temperature and pressure. Pits and sumps, metallic and
non-metallic tanks, others including plastic, glass-lined
and concrete.
CONDITIONS:
Virtually all level measurement and con-
trol applications including process conditions exhibiting
varying specific gravity and dielectric, visible vapors,
high fill/empty rates and some turbulence.
MARKETS:
All process markets including replacement of
loop-powered, ultrasonic transmitters
Performs to ±0.2" (5 mm) or 0.05% of tank height
Lexan
®
EXL or Cast Aluminum housings
Antenna horn encapsulated with Polypropylene,
Tefzel
®
(optional)
Antenna extensions of 2" (50 mm) and 8" (200 mm)
2" NPT or BSP connections (Sch. 40 maximum)
Adjustable beam pattern without removing transmitter
from vessel
Antenna output of <.01 mW (avg), <2 mW (max)
Safety Integrity Level (SIL) value of 1 (SFF 89.1%)