T R A N S M I T T E R
S P E C I F I C A T I O N S
F U N C T I O N A L / P H Y S I C A L
System Design
Measurement Principle
Input
Measured Variable
Span
Output
Type
Range
Resolution
Loop Resistance
Diagnostic Alarm
Damping
User Interface
Keypad
Indication
Digital Communication
Power
(Measured at instrument terminals)
General Purpose
Intrinsically Safe
Explosion Proof
Housing
Material
Cable Entry
Ingress Protection
Net/Gross Weight
Overall Dimensions
Aluminum
316 Stainless steel
Cast aluminum A356T6 (<0.2% copper), cast 316 SS (optional)
3
Pulse Burst Radar @ 5.8 GHz (Europe), 6.3 GHz (North America)
Liquid level, determined by the time-of-flight of a radar pulse from
transmitter to product surface and back
0.5 to 65 feet (0.2 m to 20 m)
Analog
Analog
Digital
Analog
Digital
GP/IS/XP
4 to 20 mA with HART digital signal
3.8 to 20.5 mA useable (meets NAMUR NE 43)
0 to 999" (0 to 999 cm)
0.01 mA
0.1"
350
Ω
@ 24 VDC/22 mA;
1200
1000
800
36 V
1000
Ω
400
Ω
@ 24 VDC/20 mA
(meets NAMUR NE 43)
Adjustable 0–45
3-button menu-driven
Adjustable 3.6 mA, 22 mA, HOLD
Ω
600
400
200
0
0
10
16
28.6 V
630
Ω
@ 20 mA
(350 @ 22 mA)
data entry and system security
2-line
×
8-character display
HART version 5.x compatible
16 to 36
16 to 36
VDC
VDC
20
24
30
40
VDC
16 to 28.6 VDC
General Purpose &
Explosion Proof
Intrinsically Safe
⁄
4
" NPT, M20
Type 4X (IP66)
6 lbs (2.36 kg) / 7 lbs (2.76 kg)
13.5 lbs (5.3 kg) / 14 lbs (5.7 kg)
H 10.21" (259 mm)
×
W 4.38" (111 mm)
×
D 7.40" (188 mm)
RTTE: European approval, FCC & IC: North American approval
E N V I R O N M E N T
Operating Temperature
Display Function Operating Temperature
Storage Temperature
Humidity
Electromagnetic Compatibility
Surge Protection
Shock Class
Vibration Class
10
-40 to +175° F
-5 to +160° F
-50 to +175° F
(-40 to +80° C)
(-20 to +70° C)
(-46 to +80° C)
0–99%, non-condensing
Meets CE requirements: EN 61000-6-2, EN 61000-6-4
Meets CE Requirements: EN 61326 (1000 Volts)
ANSI/ISA-S71.03 Class SA1
ANSI/ISA-S71.03 Class VC2