T10 Float Level Switch
D E S C R I P T I O N
The T10 float level switch offers industrial and munici-
pal users a low-cost solution to wide differential level
applications. The moving ballast causes a flipping
motion of the float to provide positive switching action
even under turbulent conditions. Recommended for
use in either clean or dirty liquids, it is ideal for use in
sump control, wet well applications and pilot systems.
Pump
Customer
Supplied
Control
1
⁄
2
On
F E A T U R E S
•
Differential band 20, 40, or 60 feet (determined by
cable length)
•
May be wired for automatic fill or empty cycles
•
Dry contact switch mechanism
•
Cable CSA (SJTO) approved
•
Switch chatter eliminated with moving ballast
•
Single float with simple control circuit eliminates
the need for latching devices or double switching
with two units
•
Specific gravity range of 0.6 to 1.5
•
Positive switching action—even in turbulent
conditions
•
Cable anchoring point protected by adjustable strain
relief
•
All PVC exposed components make it resistant to
water-based chemicals
•
Mounts easily by cable tie (included) or optional
cable weight
differential
band
20, 40,
or 60 ft.
(6, 12,
or 18 m)
differential
band
1
⁄
2
differential
band
Pump
Off
A P P L I C A T I O N S
•
Water and wastewater
•
PVC compatible caustics
•
PVC compatible chemicals
•
PVC compatible acids
S P E C I F I C A T I O N S
Switch type
Process temperature
Ambient temperature
Specific gravity
Differential band
Materials of construction
Cable size
Non-inductive switch ratings
SPDT dry contact
+140° F (+60° C) maximum
+32° to +140° F (0° to +60° C)
0.6 minimum / 1.5 maximum
18 inches (457 mm) minimum / 60 feet (18 meters) maximum
Polyvinylchloride (PVC) with adjustable neoprene strain relief
and butyl cosmetic ring
18 AWG (3 x 1.5 mm) 41 strands
21.00 @ 120 VAC / 21.00 @ 240 VAC
14.00 @ 30 VDC / 0.60 @ 120 VDC / 0.30 @ 240 VDC