欢迎访问ic37.com |
会员登录 免费注册
发布采购

1600XA 参数 Datasheet PDF下载

1600XA图片预览
型号: 1600XA
PDF下载: 下载PDF文件 查看货源
内容描述: 单,双,三路输出DC / DC转换器 [Single, Dual, Triple Output DC/DC Converter]
分类和应用: 转换器
文件页数/大小: 3 页 / 154 K
品牌: MAKE-PS [ MAKE-PS ]
 浏览型号1600XA的Datasheet PDF文件第2页浏览型号1600XA的Datasheet PDF文件第3页  
www.make-ps.com
E-mail:info@make-ps.com
1600XA series
F
EATURES
Single, Dual, Triple Output
DC/DC Converter
6 sided Continuous Shielding
Synchronization
10W/In
3
Power Density
Wide 2:1 Input Voltage Range
Efficiency to 82%
-55
o
C to +85
o
C Operation
Meets MIL-STD-810 & MIL-STD-202
D
ESCRIPTIONS
The 1600XA series 16 watts high performance DC/DC
converters are cost effective solution to the high reliability
and performance requirements of power distribution
systems in applications ranging from high speed data
communications equipment to industrial robotic systems.
The 1600XA series operates from wide (2:1) input voltage
ranges of 9 to 18, 18 to 36 or 36 to 72VDC; providing single,
dual and triple output combinations of 5, 12, 15, ±5, ±12, ±15,
5/±12 and 5/±15 VDC. All models are packaged in compact,
low profile 2” X 2” X 0.4” metal cases.
I
NPUT
C
HARACTERISTICS
Min Typ Max Unit/Comments
Input Voltage Range
12 VDC Input Models
12
9
24 VDC Input Models
18 24
48 VDC Input Models
36 48
Remote On / OFF Control
Supply ON
3.5
Supply OFF
0
Logic Referenced to Negative Input
Input Filter
18
36
72
VDC
VDC
VDC
VDC or Open Circuit
VDC
0.8
Pi Filter
O
UTPUT
C
HARACTERISTICS
Min Typ Max Unit/Comments
Output Voltage Accuracy
Single & Dual Outputs
Triple Outputs - Primary
- Auxiliaries
Output Voltage Trim
Voltage Balance:
Dual Outputs
Triple Outputs (Auxiliaries)
Minimum Load
Line Regulation
Single & Dual Outputs
Triple Outputs - Primary
- Auxiliaries
Load Regulation
Single Outputs
Dual Outputs
Triple Outputs - Primary
- Auxiliaries
Ripple/Noise
Short Circuit Protection
Transient Recovery Time
Temperature Coefficient
Over Voltage Protection
1
2
3
G
ENERAL
C
HARACTERISTICS
Efficiency
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Acceleration
Shock
Vibration
Altitude
Switching Frequency
Unit/Comments
See Model Selection Guide
1400 VDC Min., 1 minute
Meets requirements of MIL-STD-202F, method
301
>10
9
Ohms; Meets requirements of MIL-STD-202F,
method 302, test condition B
140 pF
Per MIL-STD-810E, method 513.4, procedure II.
Operational test (centrifuge) 12g’s (manned aero-
space vehicles)
Per MIL-STD-801E, method 516.4, procedure I.
Functional shock 40g’s.
Per MIL-STD-810E, method 514.4, procedure I,
category 6 (equipment installed in helicopters).
Per MIL-STD-810E, method 500.3, procedure III
Rapid decompression, 40K ft.
100 kHz, Min.
±1.0
±1.0
±6.0
±5
%
%
1
%
1
%
1
±1.0 %; Equal Output Loads
±1.0 %; Equal Output Loads
10% Full Load
±0.5 %
2
±0.2 %
2
±6.0 %
2
%
3
%
3
; Equal Loads
%
3
%
3
; Equal Loads
% of Vout
Continuous, Auto-
matic Recovery
200
μS
to within1% error
band for 50% step
load change
±0.01 % per
o
C
See Model Selection Guide
±0.2
±1.0
±0.5
±6.0
2
= Output voltage at nominal line & FL
= % Output voltage measured from min. input line to maximum
= Output voltage measured from FL to 10% Load
>> 1