www.make-ps.com
E-mail:info@make-ps.com
200FR series
F
EATURES
•
•
•
•
•
Single & Dual Output
DC/DC Converter
Up to 61 % Efficiency
Single and Dual Output, 2 watt converter
Available in 5, 12, 24 and 48 VDC Inputs
Industry Standard Pinout
Short Circuit Protection
D
ESCRIPTIONS
The 200FR series 2 watt power modules are specially
designed to provide low output ripple, and tight regulation in
a low-profile 24 pin DIP package. The series consists of 20
models with input voltages of 5V, 12V, 24V and 48V, and offers
regulated output voltages of 5V, 12V, 15V, ±12V and ±15V.
The -25
o
C to +71
o
C operating temperature range makes it
ideal for data communication equipment, mobile battery
driven equipment, distributed power systems, telecommu-
nication equipment, mixed analog/digital subsystems, auto-
matic test instrumentation and industrial robot systems.
I
NPUT
C
HARACTERISTICS
Min Typ Max Unit/Comments
Input Voltage
5 VDC Input Models
4.5
12 VDC Input Models 10.8
24 VDC Input Models 21.6
48 VDC Input Models 43.2
Input Fuse Requirements
5 VDC Input Models
12 VDC Input Models
24 VDC Input Models
48 VDC Input Models
Reverse Polarity Input Current
Short Circuit Input Power
Input Filter
5
12
24
48
1500
700
350
135
5.5
13.2
26.4
52.8
VDC
VDC
VDC
VDC
O
UTPUT
C
HARACTERISTICS
Output Voltage Set Point
Output Voltage Balance
(Duals)
Line Regulation
Min Typ Max Unit/Comments
±2.0 ±4.0 % Output voltage at
nominal line & FL
±1.0 ±3.0 % Equal Output
Loads
±0.2 ±0.5 % Output voltage
measured from
min. input line to
maximum
±0.2 ±0.5 % Output voltage
measured from FL
to 10% load
45 50 mV p-p, Nom.Line
@FL, 20MHz B.W.,
using 1
μf
bypass
capacitor
75 mV p-p, Over Line,
Load & Temp., 20
MHz B.W.,
using 1
μf
bypass
capacitor
%Rated Output Load
120
Continuous,
Automatic Recovery
±6 % deviation of Vout
for a 50% load
change
50
μS
for 50% load
change
±0.01 ±0.02 % per degree C
mA; Slow blow type
mA; Slow blow type
mA; Slow blow type
mA; Slow blow type
0.5 Amp
2000 mW
Pi Filter
G
ENERAL
C
HARACTERISTICS
Switching Frequency
Isolation Voltage
Isolation Resistance
Isolation Capacitance
MTBF (MIL-HBK-217F)
Min Typ Max Unit/Comments
kHz
40 80
VDC, 1 minute
500
Mohm, 500VDC
1000
100 150 pF, 100kHz, 1Volt
Thousand Hours,
800
+25
o
C, Ground
Benign
Load Regulation
Ripple/Noise
Ripple/Noise
Overload Protection
Short Circuit Protection
Transient Response
Deviation
Transient Recovery Time
Temperature Coefficient
>> B-21