欢迎访问ic37.com |
会员登录 免费注册
发布采购

805D24 参数 Datasheet PDF下载

805D24图片预览
型号: 805D24
PDF下载: 下载PDF文件 查看货源
内容描述: 单,双,三路输出DC / DC转换器 [Single, Dual, Triple Output DC/DC Converter]
分类和应用: 转换器
文件页数/大小: 3 页 / 161 K
品牌: MAKE-PS [ MAKE-PS ]
 浏览型号805D24的Datasheet PDF文件第2页浏览型号805D24的Datasheet PDF文件第3页  
www.make-ps.com
E-mail:info@make-ps.com
800 series
F
EATURES
Single, Dual, Triple Output
DC/DC Converter
Synchronization
6 sided Continuous Shielding
9.38W/In
3
Power Density
Efficiency to 82%
VDE / EN 60950 Approved
>1,000,000 Hours MTBF
D
ESCRIPTIONS
The 800 series is family of miniature, high performance and
high reliability DC/DC converters. The 800 series operates
over 2:1 input voltage ranges of 9 to 18, 18 to 36 or 36 to
72VDC; providing single, dual and triple output combinations
of 5, 12, 15, ±5, ±12, ±15, 5/±12 and 5/±15 VDC. Standard
features include 500VDC input/output isolation, efficiency
as high as 82%, tight line/load regulation and low output
ripple and noise. All 24 models are packaged in compact,
low profile 1” X 2” X 0.4” metal cases.
I
NPUT
C
HARACTERISTICS
Min Typ Max Unit/Comments
Input Voltage Range
12 VDC Input Models
9
12
24 VDC Input Models
18 24
48 VDC Input Models
36 48
Remote On / OFF Control
Supply ON
Supply OFF
Logic Referenced to Negative Input
Input Filter
Input Fuse Rating
18
36
72
VDC
VDC
VDC
0 VDC to 0.6 VDC
1 VDC to 5 VDC
LC Type
See Model Selection
Guide
O
UTPUT
C
HARACTERISTICS
Min Typ Max Unit/Comments
Output Voltage Accuracy
Single & Dual Outputs
Triple Outputs - Primary
- Auxiliaries
Voltage Balance:
Dual Outputs
Triple Outputs (Auxiliaries)
Minimum Load
10%
Line Regulation
Single & Dual Outputs
Triple Outputs - Primary
- Auxiliaries
Load Regulation
Single Outputs
Dual Outputs
Triple Outputs - Primary
- Auxiliaries
Ripple/Noise
Short Circuit Protection
Transient Recovery Time
Temperature Coefficient
Over Voltage Protection
±1.0 %
1
±1.0 %
1
±6.0 %
1
±1.0 %; Equal Output Loads
±1.0 %; Equal Output Loads
Full Load
±0.5 %
2
±0.5 %
2
5.0 %
2
%
3
%
3
; Equal Loads
%
3
%
3
; Equal Loads
% of Vout
(20 MHz B.W.)
Continuous, Auto-
matic Recovery
200
μS
to within1% error
band for 50% step
load change
±0.01 % per
o
C
See Model Selection Guide
±0.5
±1.0
±0.5
±6.0
2
G
ENERAL
C
HARACTERISTICS
Switching Frequency
Isolation Voltage
Isolation Resistance
MTBF (MIL-HBK-217F)
Min Typ Max Unit/Comments
kHz
100
VDC, 1 minute
500
Mohm, 500VDC
1000
Million Hours,
1
+25
o
C, Ground
Benign
1
2
3
= Output voltage at nominal line & FL
= % Output voltage measured from min. input line to maximum
= Output voltage measured from FL to 10% Load
>> B-85