ELECTRICAL CHARACTERISTICS FOR 5V SUPPLY VOLTAGE
T
A
= -40° to +85° typical values at T
A
= +27°C, V
DD
= 4.5V… 5V, f
O
= 30 MHz, Output Load = 15 pF, unless otherwise specified.
C
C,
Parameter
Output Load
Crystal Frequency Range
when Output Load is Maximum 30pF
Crystal Frequency Range
when Output Load is Maximum 50pF
Supply Current
MAS9281 (f
o
)
MAS9281 (f
o
/2)
MAS9281 (f
o
/4)
MAS9281 (f
o
/8)
MAS9281 (f
o
/16)
MAS9281 (f
o
/512)
Output Voltage Range
Rise and Fall Time
Start-up Time
Output Symmetry
Tri State Output Buffer
OFF State
ON State
Power Down High Level Output
Voltage: Ioh=16 mA ,Vdd = 5V
(Test measurement, see fig. 1, p. 5)
PD Pull-up resistance
Design value
Symbol
Min
Typ
15
Max
50
60.00
40.00
Unit
pF
MHz
MHz
mA
Note
f
o
f
o
I
DD
10.00
10.00
Note 1
See fig. 2
11.3
8.0
7.7
7.6
7.3
7.1
Vdd ± 0.5
3
T
START
45
PD
0
1.6
0.55
V
DD
4.7
2
48-52
55
4
Vpp
ns
ms
%
V
V
OH
Rup1
V
900k
ohm
Note1:
MAS9281AN – MAS9281AT and MAS9281A0 – MAS9281A4 maximum frequency is 44MHz
PIN DESCRIPTION
Pin Description
Power Down
Crystal Oscillator Output
Crystal Oscillator Input
Power Supply Ground
Power Supply Voltage
Buffer Output
Symbol
PD
X2
X1
VSS
VDD
OUT
x-coordinate
146
312
553
695
178
597
y-coordinate
140
140
140
140
826
826
Note:
Because the substrate of the die is internally connected to GND, the die has to be connected to GND or
left floating. Please make sure that GND is the first pad to be bonded. Pick-and-place and all component
assembly are recommended to be performed in ESD protected area.
Note:
Pad coordinates are measured from the left bottom corner of the chip to the center of the pads. The
coordinates may vary depending on sawing width and location, however, distances between pads are accurate.
3 (6)