DATASHEET
75V MODULE
NOTES
1. Capacitance and ESR
DC
measured at 25°C per
Document Number 1007239 available at
www.maxwell.com.
2. Per Maxwell Document 1007239 available at
www.maxwell.com.
½ CV
3. Maximum Peak current (1 sec) =
C x ESR
DC
+ 1
4. After 72 hours at 25°C and rated voltage. Initial
leakage current can be higher.
0.12V
2
5. Per IEC 62391-2, P
d
= ESR x mass
DC
2
V
6. P
max
=
4 x ESR
DC
x mass
½ CV
2
7. E
max
=
3,600 x mass
½ CV
2
8. E
stored
=
3,600
9. Cycle per Document Number 1007239 available at
www.maxwell.com.
10. No more than 10% decrease in capacitance from
minimum initial capacitance or 50% increase in ESR
from maximum initial ESR.
11. Tested at 1 kV DC.
12. For a given application, sufficient cooling must be
provided to keep cell case temperatures below 65°.
See R
th
.
13. Duration = 60 seconds. Not intended as an operating
parameter.
14. Absolute maximum voltage non repeated, not to
exceed 1 second.
MOUNTING RECOMMENDATIONS
Please refer to the user manual for installation
recommendations
MARKINGS
Products are marked with the following information:
Rated capacitance, rated voltage, product number,
name of manufacturer, positive and negative terminal,
warning marking, serial number.