MX27C2100/27C2048
DC PROGRAMMING CHARACTERISTICS TA = 25oC ±5°C
SYMBOL
VOH
VOL
VIH
PARAMETER
MIN.
MAX.
UNIT
V
CONDITIONS
IOH = -0.40mA
IOL = 2.1mA
Output High Voltage
2.4
Output Low Voltage
0.4
V
Input High Voltage
2.0
VCC + 0.5
0.8
V
VIL
Input Low Voltage
-0.3
-10
V
ILI
Input Leakage Current
A9 Auto Select Voltage
VCC Supply Current (Program & Verify)
VPP Supply Current(Program)
Fast Programming Supply Voltage
Fast Programming Voltage
10
uA
V
VIN = 0 to 5.5V
VH
11.5
12.5
50
ICC3
IPP2
VCC1
VPP1
mA
mA
V
30
CE = VIL, OE = VIH
6.00
12.5
6.50
13.0
V
AC PROGRAMMING CHARACTERISTICS TA = 25oC ±5°C
SYMBOL
tAS
PARAMETER
MIN.
2.0
2.0
2.0
0
MAX.
UNIT
us
us
CONDITIONS
Address Setup Time
OE Setup Time
tOES
tDS
Data Setup Time
us
us
us
ns
us
tAH
Address Hold Time
Data Hold Time
tDH
2.0
0
tDFP
tVPS
tPW
Out put Enable to Output Float Delay
VPP Setup Time
130
105
2.0
95
PGM Program Pulse Width
VCC Setup Time
us
us
us
ns
tVCS
tCES
tOE
2.0
2.0
CE Setup Time
Data valid from OE
150
P/N: PM0158
REV. 4.3, AUG. 22, 2001
10