欢迎访问ic37.com |
会员登录 免费注册
发布采购

MX29LV004CBTI-90G 参数 Datasheet PDF下载

MX29LV004CBTI-90G图片预览
型号: MX29LV004CBTI-90G
PDF下载: 下载PDF文件 查看货源
内容描述: 4M- BIT [ 512K ×8 ] CMOS单电压3V仅限于Flash存储器 [4M-BIT [512K x 8] CMOS SINGLE VOLTAGE 3V ONLY FLASH MEMORY]
分类和应用: 闪存存储内存集成电路光电二极管ISM频段
文件页数/大小: 59 页 / 517 K
品牌: MCNIX [ MACRONIX INTERNATIONAL ]
 浏览型号MX29LV004CBTI-90G的Datasheet PDF文件第3页浏览型号MX29LV004CBTI-90G的Datasheet PDF文件第4页浏览型号MX29LV004CBTI-90G的Datasheet PDF文件第5页浏览型号MX29LV004CBTI-90G的Datasheet PDF文件第6页浏览型号MX29LV004CBTI-90G的Datasheet PDF文件第8页浏览型号MX29LV004CBTI-90G的Datasheet PDF文件第9页浏览型号MX29LV004CBTI-90G的Datasheet PDF文件第10页浏览型号MX29LV004CBTI-90G的Datasheet PDF文件第11页  
MX29LV004C T/B
TABLE 4. MX29LV004C T/B COMMAND DEFINITIONS
Command
Bus
First Bus
Cycle
Second Bus
Cycle
Third Bus
Cycle
Fourth Bus
Cycle
Data
Fifth Bus
Cycle
Addr
Sixth Bus
Cycle
Data Addr
Data
Cycle Addr
Reset
Read
Read Silicon ID
Sector Protect
Verify
Program
Chip Erase
Sector Erase
Sector Erase Suspend
Sector Erase Resume
CFI Query
4
6
6
1
1
1
1
1
4
4
Data Addr
Data Addr
Data Addr
XXXH F0H
RA
RD
55H
55H
555H
555H
90H ADI
90H (SA)
x02H
555H AAH 2AAH
555H AAH 2AAH
555H AAH 2AAH
XXXH B0H
XXXH 30H
AAH
98
55H
55H
55H
555H
555H
555H
A0H PA
DDI
00H
01H
PD
2AAH 55H
2AAH 55H
555H 10H
SA
30H
555H AAH 2AAH
555H AAH 2AAH
80H 555H AAH
80H 555H AAH
Note:
1. ADI = Address of Device identifier; A1=0, A0 = 0 for manufacturer code,A1=0, A0 = 1 for device code. A2-A17=do
not care.
(Refer to table 3)
DDI = Data of Device identifier : C2H for manufacture code, B5H/B6H (Top/Bottom) for device code.
X = X can be VIL or VIH
RA=Address of memory location to be read.
RD=Data to be read at location RA.
2. PA = Address of memory location to be programmed.
PD = Data to be programmed at location PA.
SA = Address of the sector to be erased.
3. The system should generate the following address patterns: 555H or 2AAH to Address A11~A0.
Address bit A12~A18=X=Don't care for all address commands except for Program Address (PA) and Sector
Address (SA). Write Sequence may be initiated with A12~A18 in either state.
4. For Sector Protect Verify operation:If read out data is 01H, it means the sector has been protected. If read out data
is 00H, it means the sector is still not being protected.
5. Any number of CFI data read cycle are permitted.
P/N:PM1148
REV. 1.3, APR. 24, 2006
7