55W Dual Output with Battery Charger(USP Function)
Features :
ADD-55
series
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Battery low protections
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 45KHz
2 years warranty
SPECIFICATION
MODEL
OUTPUT NUMBER
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
PROTECTION
OVER VOLTAGE
ADD-55A
CH1
13.8V
2.5A
0 ~ 3.5A
52.58W
100mVp-p
3.0%
0.5%
0.5%
--------
--------
--------
--------
1600ms, 50ms/115VAC at full load
CH1: 12 ~ 14.5V
1.0%
1.0%
1.0%
800ms, 50ms/230VAC
80ms/230VAC
88 ~ 264VAC
47 ~ 63Hz
71%
1.6A/115VAC
1A/230VAC
COLD START 20A/115VAC
40A/230VAC
<1mA / 240VAC
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1:14.49 ~ 18.63V
CH1:28.98 ~ 37.26V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
AC fail CN1 PIN2
FUNCTION
DC ALARM SIGNAL(OPTIONAL)
Battery low under charge voltage 82.5% 2% CN1 PIN1
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
Normal 0.8V max. Abnormal 5V 0.5V
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0 ~ 50 ) on CH1 output
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
/ 70% RH
74%
CH2
5V
3A
0 ~ 4A
CH3
13.4V
0.23A
--------
ADD-55B
CH1
27.6V
1.3A
0 ~ 2A
55.12W
150mVp-p
CH1: 24 ~ 29V
1.0%
1.0%
1.0%
150mVp-p
3.0%
0.5%
0.5%
--------
--------
--------
--------
CH2
5V
3A
0 ~ 4A
CH3
26.5V
0.16A
--------
RIPPLE & NOISE (max.)
Note.2
100mVp-p
16ms/115VAC at full load
124 ~ 370VDC
SAFETY &
EMC
(Note 4)
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
EMI CONDUCTION & RADIATION
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
HARMONIC CURRENT
EMS IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
241.3K hrs min. MIL-HDBK-217F (25 )
159*97*38mm (L*W*H)
0.57Kg; 24pcs/13.7Kg/0.75CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:ADD-55-SPEC 2008-10-08