欢迎访问ic37.com |
会员登录 免费注册
发布采购

ELN-30-15 参数 Datasheet PDF下载

ELN-30-15图片预览
型号: ELN-30-15
PDF下载: 下载PDF文件 查看货源
内容描述: 30W单路输出开关电源 [30W Single Output Switching Power Supply]
分类和应用: 开关
文件页数/大小: 3 页 / 256 K
品牌: MEANWELL [ MEAN WELL ENTERPRISES CO., LTD. ]
 浏览型号ELN-30-15的Datasheet PDF文件第2页浏览型号ELN-30-15的Datasheet PDF文件第3页  
30W Single Output Switching Power Supply
Features :
ELN-30
series
Universal AC input / Full range
Protections: Short circuit / Over current / Over voltage
Cooling by free air convection
Built-in constant current limiting circuit with adjustable OCP level
Optional dimming function : 1.1~10VDC (D type) or PWM (P type) controlled
Fully isolated plastic case with IP64 level
Class
power unit, no FG
Class 2 power unit
Pass LPS
Suitable for LED lighting and moving sign applications (Note.8)
100% full load burn-in test
Low cost
2 years warranty
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
ELN-30-5
5V
5A
0 ~ 5A
25W
4.5 ~ 5.5V
LED OPERATION VOLTAGE
Note.7
3 ~ 5V
ELN-30-9
9V
3 ~ 9V
3.4A
0 ~ 3.4A
30.6W
100mVp-p
8.7 ~ 10.5V
ELN-30-12
12V
3 ~ 12V
2.5A
0 ~ 2.5A
30W
120mVp-p
10.8 ~ 13.2V
LPS
IP64
ELN-30-15
15V
3 ~ 15V
2A
0 ~ 2A
30W
120mVp-p
13.5 ~ 16.5V
ELN-30-24
24V
3 ~ 24V
1.25A
0 ~ 1.25A
30W
150mVp-p
( for 48V only)
( except for 48V )
ELN-30-27
27V
3 ~ 27V
1.12A
0 ~ 1.12A
30.24W
150mVp-p
24.3 ~ 29.7V
ELN-30-48
48V
3 ~ 48V
0.63A
0 ~ 0.63A
30.24W
250mVp-p
43.2 ~ 52.8V
RIPPLE & NOISE (max.)
Note.2
80mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (max.)
LEAKAGE CURRENT
OVER CURRENT
PROTECTION
OVER VOLTAGE
21.6 ~ 26.4V
Can be adjusted by internal potentiometer SVR1
-25% ~ 3%. Can be adjusted by internal potentiometer SVR2
5.0%
1.0%
2.0%
Note.6
500ms, 80ms / 230VAC
1000ms, 80ms / 115VAC at full load
50ms/230VAC
Note.4
90 ~ 264VAC
16ms/115VAC at full load
127 ~ 370VDC
80%
82%
82%
85%
85%
87%
47 ~ 63Hz
75%
0.75A/115VAC 0.48A/230VAC
COLD START 60A/230VAC
0.25mA / 240VAC
95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
5.75 ~ 6.75V
11 ~ 13.5V
13.8 ~ 16V
17.5 ~ 21V
28 ~ 32V
31 ~ 36.4V
54 ~ 60V
Protection type : Shut down o/p voltage, re-power on to recover
FUNCTION DIMMING CONTROL
(OPTIONAL)
1.1 ~ 10VDC or PWM signal : 100Hz ~ 3KHz
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY &
EMC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
-20 ~ +60
-40 ~ +80
0.03%/
(Refer to "Derating Curve")
, 10 ~ 95% RH
(0 ~ 50
)
20 ~ 90% RH non-condensing
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1310, CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved ; design refer to TUV EN60950-1
I/P-O/P:3KVAC
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
628.3Khrs min. MIL-HDBK-217F (25 )
145*47*30mm (L*W*H)
0.26Kg; 60pcs/16.6Kg/1.25CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Constant current operation region is within the specified output voltage range above. This is the suitable operation region for LED related applications.
8. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
File Name:ELN-30-SPEC 2012-03-20