40W AC-DC Single Output Desktop
Features :
GS40
series
Universal AC input / Full range
No load power consumption<0.3W
Pass energy star (CEC) level
for full series
Meet energy star (CEC) level
for full series
Meet EISA 2007(Energy Independence and Security Act)
3 pole AC inlet IEC320-C14
Class power ( with earth pin)
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
LED indicator for power on
Approvals: UL / CUL / TUV / BSMI / CCC / CB / FCC / CE
Pass LPS for full series
2 years warranty
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
OUTPUT
VOLTAGE TOLERANCE
Note.4
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
Note.5
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
GS40A05-P1J GS40A07-P1J GS40A09-P1J GS40A12-P1J GS40A15-P1J GS40A18-P1J GS40A24-P1J GS40A48-P1J
GS40A05
Note.2
5V
GS40A07
7.5V
5.34A
0 ~ 5.34A
40W
100mVp-p
5.0%
1.0%
5.0%
GS40A09
9V
4.45A
0 ~ 4.45A
40W
100mVp-p
5.0%
1.0%
5.0%
GS40A12
12V
3.34A
0 ~ 3.34A
40W
100mVp-p
3.0%
1.0%
3.0%
GS40A15
15V
2.67A
0 ~ 2.67A
40W
100mVp-p
3.0%
1.0%
3.0%
GS40A18
18V
2.22A
0 ~ 2.22A
40W
150mVp-p
3.0%
1.0%
3.0%
GS40A24
24V
1.67A
0 ~ 1.67A
40W
180mVp-p
2.5%
1.0%
2.5%
GS40A48
48V
0.84A
0 ~ 0.84A
40W
240mVp-p
2.5%
1.0%
2.5%
5A
0 ~ 5A
25W
5.0%
1.0%
5.0%
RIPPLE & NOISE (max.)
Note.3
100mVp-p
Note.7
600ms, 30ms / 230VAC
600ms, 30ms / 115VAC at full load
50ms / 230VAC
15ms / 115VAC at full load
90 ~ 264VAC 135 ~ 370VDC
47 ~ 63Hz
80.5%
1A / 115VAC
65A / 230VAC
0.75mA / 240VAC
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.25 ~ 6.75V
7.88 ~ 10.13V 9.45 ~ 12.15V 12.6 ~ 16.2V 15.75 ~ 20.25V 18.9 ~ 24.3V
Protection type : Shut down o/p voltage, re-power on to recover
0 ~ +60
(Refer to output load derating curve)
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03% / (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
85.5%
0.5A / 230VAC
85%
89%
89.5%
90%
91%
92%
25.2 ~ 32.4V
50.4 ~ 64.8V
SAFETY &
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC
EMI CONDUCTION & RADIATION
Compliance to EN55022 class B, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254 class B
(Note. 6)
HARMONIC CURRENT
Compliance to EN61000-3-2,3, GB17625.1
EMS IMMUNITY
OTHERS
MTBF
DIMENSION
PACKING
PLUG
CABLE
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
711Khrs min. MIL-HDBK-217F(25
125*50*31.5mm (L*W*H)
0.31Kg; 40pcs/13.4Kg/0.91CUFT
Standard type P1J: 2.1
* 5.5
* 11mm, tuning fork type, center positive for stock ; Other type available by customer requested
See page 2 ; Other type available by customer requested
)
CONNECTOR
NOTE
1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
7. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:GS40-SPEC 2008-10-22