100W Single Output without PFC Function
Features :
LPS-100
series
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fix switching frequency at 134KHz
2 years warranty
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
EFFICIENCY(Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 4)
LPS-100-3.3 LPS-100-5
3.3V
20A
0 ~ 20A
66W
3 ~ 3.6V
3.0%
0.5%
5V
20A
0 ~ 20A
100W
100mVp-p
4.5 ~ 5.7V
3.0%
0.5%
LPS-100-7.5 LPS-100-12 LPS-100-13.5 LPS-100-15 LPS-100-24 LPS-100-27 LPS-100-48
7.5V
13.3A
0 ~ 13.3A
99.75W
100mVp-p
6 ~ 9V
2.0%
0.5%
12V
8.4A
0 ~ 8.4A
100.8W
100mVp-p
10 ~ 13.2V
2.0%
0.5%
13.5V
7.5A
0 ~ 7.5A
101.25W
100mVp-p
12 ~ 15V
2.0%
0.5%
15V
6.7A
0 ~ 6.7A
100.5W
100mVp-p
13.5 ~ 18V
2.0%
0.5%
1.5%
24V
4.2A
27V
3.8A
48V
2.1A
0 ~ 2.1A
100.8W
200mVp-p
41 ~ 56V
1.0%
0.5%
0.5%
0 ~ 4.2A(6A 10s) 0 ~ 3.8A
100.8W(144W 10s) 102.6W
150mVp-p
20 ~ 26.4V
1.0%
0.5%
0.5%
150mVp-p
26 ~ 32V
1.0%
0.5%
0.5%
RIPPLE & NOISE (max.)
Note.2
150mVp-p
2.0%
2.0%
800ms, 50ms/230VAC
20ms/230VAC
47 ~ 63Hz
69%
2.3A/115VAC
77%
1.5%
1.5%
1.5%
1200ms, 50ms/115VAC at full load
248 ~ 370VDC
79%
79%
20ms/115VAC at full load
88 ~ 132VAC / 176 ~ 264VAC auto switch
77%
1.5A/230VAC
60A/230VAC
80%
80%
81%
81%
COLD START 30A/115VAC
<1mA / 240VAC
105 ~ 140% (+24V: above 6.5A)
rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8 ~ 4.45V
5.75 ~ 6.75V 9.4 ~ 10.9V
13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V
27.6 ~ 32.4V 33.7 ~ 39.2V 57.6 ~ 67.2V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +60 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.05%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,11, light industry level, criteria A
203.6Khrs min. MIL-HDBK-217F (25
222*62*32mm (L*W*H)
0.45Kg; 24pcs/12.5Kg/1.39CUFT
)
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
NOTE
DIMENSION
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. If the input range 85V-89V, the output load is changed from 0A-rated load, There will be reduced 20V for 1second (LPS-100-24).
6. Mounting holes M1 and M2 should be grounded for EMI purposes.
File Name:LPS-100-SPEC 2011-08-10