欢迎访问ic37.com |
会员登录 免费注册
发布采购

MPS-30-48 参数 Datasheet PDF下载

MPS-30-48图片预览
型号: MPS-30-48
PDF下载: 下载PDF文件 查看货源
内容描述: 30W单输出医疗类型 [30W Single Output for Medical Type]
分类和应用: 医疗
文件页数/大小: 2 页 / 506 K
品牌: MEANWELL [ MEAN WELL ENTERPRISES CO., LTD. ]
 浏览型号MPS-30-48的Datasheet PDF文件第2页  
30W Single Output for Medical Type
Features :
Universal AC input / Full range
Low leakage current
0.3mA
MPS-30
series
Protections: Short circuit / Overload / Over voltage / Over temperature
Fixed switching frequency at 100KHz
Low cost
High reliability
3 years warranty
EN60601-1
IEC60601-1
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
MPS-30-5
5V
5A
0 ~ 5A
25W
3.0%
1.0%
2.0%
500ms, 30ms/230VAC
70ms/230VAC
47 ~ 63Hz
72%
0.8A/115VAC
75%
0.5A/230VAC
76%
77%
78%
78%
88 ~ 264VAC auto switch
MPS-30-12
12V
2.5A
0 ~ 2.5A
30W
120mVp-p
3.0%
1.0%
1.0%
12ms/115VAC at full load
120 ~ 370VDC
MPS-30-15
15V
2A
0 ~ 2A
30W
150mVp-p
3.0%
0.5%
1.0%
MPS-30-24
24V
1.2A
0 ~ 1.2A
28.8W
240mVp-p
3.0%
0.5%
1.0%
MPS-30-27
27V
1.1A
0 ~ 1.1A
29.7W
240mVp-p
3.0%
0.5%
1.0%
MPS-30-48
48V
0.6A
0 ~ 0.6A
28.8W
240mVp-p
2.0%
0.5%
1.0%
RIPPLE & NOISE (max.)
Note.2
80mVp-p
500ms, 30ms/115VAC at full load
COLD START 30A/230VAC
<0.3mA / 264VAC
Above 105%
rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.5 ~ 6.75V
13.2 ~ 16.2V
16.5 ~ 20.25V
26.4 ~ 32.4V
29.7 ~ 36.45V
52.8 ~ 64.8V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Tj 135 typically (U1) detect on main control IC
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL2601-1, TUV EN60601-1, IEC60601-1 approved
I/P-O/P:4KVAC
I/P-FG:1.5KVAC
O/P-FG:SHORT
SAFETY &
EMC
(Note 4)
ISOLATION RESISTANCE
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION
Compliance to EN55011 (CISPR11) Class B
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, medical level, criteria A
547Khrs min. MIL-HDBK-217F (25
101.6*65.8*23.5mm (L*W*H)
0.16Kg; 90pcs/15.8Kg/1.02CUFT
)
OTHERS
NOTE
DIMENSION
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:MPS-30-SPEC 2010-11-29