100W Single Output Switching Power Supply
Features :
PLC-100
series
Universal AC input / Full range
High efficiency 90%
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Built-in active PFC function
UL1310 class 2 power unit
Pass LPS
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
2 years warranty
F
110
M
M
SELV
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
PLC-100-12
12V
Note.6
5A
Note.6
0 ~ 5A
Note.6
60W
LPS
PLC-100-20
20V
15 ~ 20V
4.8A
0 ~ 4.8A
96W
150mVp-p
17 ~ 20V
3.6 ~ 4.8A
3.0%
( for 48V only)
( except for 48V )
PLC-100-15
15V
11.25 ~ 15V
5A
0 ~ 5A
75W
150mVp-p
12.8 ~ 15V
3.75 ~ 5A
3.0%
PLC-100-24
24V
18 ~ 24V
4A
0 ~ 4A
96W
150mVp-p
20.4 ~ 24V
3 ~ 4A
3.0%
PLC-100-27
27V
20.25 ~ 27V
3.55A
0 ~ 3.55A
95.85W
150mVp-p
23 ~ 27V
2.6 ~ 3.55A
3.0%
PLC-100-36
36V
27 ~ 36V
2.65A
0 ~ 2.65A
95.4W
150mVp-p
30.6 ~ 36V
2 ~ 2.65A
2.0%
PLC-100-48
48V
36 ~ 48V
2A
0 ~ 2A
96W
200mVp-p
40.8 ~ 48V
1.5 ~ 2A
2.0%
CONSTANT CURRENT REGION
Note.4
9 ~ 12V
RIPPLE & NOISE (max.)
Note.2
150mVp-p
VOLTAGE ADJ. RANGE
(Vo ADJ)
10.2 ~ 12V
CURRENT ADJ. RANGE
(Io ADJ)
3.75 ~ 5A
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER CURRENT (Typ.)
Note.4
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
3.0%
1.0%
2.0%
1200ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load
60ms/230VAC 30ms/115VAC at full load
Note.5
90 ~ 264VAC
127 ~ 370VDC
47 ~ 63Hz
PF>0.95/115VAC, PF>0.95/230VAC at full load (Please refer to "Power Factor Characteristic" curve)
84.5%
86.5%
90%
90%
90%
0.45A/230VAC
90%
20V ~ 48V:1.1A/115VAC
89%
0.55A/230VAC
12V:0.8A/115VAC 0.4A/230VAC
COLD START 40A/230VAC
<0.75mA / 240VAC
95 ~ 102%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
13 ~ 16V
16.5 ~ 20V
22 ~ 27V
27 ~ 34V
30 ~ 36V
39 ~ 48V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
90
10
(RTH2)
(Refer to "Derating Curve")
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +50
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/
(0 ~ 50
)
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
I/P-O/P:3.75KVAC
I/P-FG:1.88KVAC
O/P-FG:0.5KVAC
52 ~ 64V
15V:0.9A/115VAC
SAFETY STANDARDS
Note.7
UL1310 Class 2, TUV EN60950-1, EN61347-1, EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V) ; J61347-1, J61347-2-13 approved
SAFETY &
EMC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2,-3, Class C ( 70% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level, (surge 4KV), criteria A
297.9Khrs min. MIL-HDBK-217F (25
200.5*69.5*35mm (L*W*H)
0.52Kg; 25pcs/14Kg/0.65CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltage. Please check the static characteristics for more details.
6. This is the maximum possible output current and power. Over load protection may be activated slightly below this level to comply with the requirement
of UL1310 class 2.
7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name:PLC-100-SPEC 2011-07-28