60W Single Output LED Power Supply
Features :
Universal AC input / Full range
PLN-60
series
Fully isolated plastic case with IP64 level
Built-in constant current limiting circuit with adjustable OCP level
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in active PFC function
IP64 design for indoor or outdoor installations
UL1310 Class 2 power unit
Cooling by free air convection
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
2 years warranty
F
110
M
M
SELV
EQUIVALENT
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
PLN-60-12
12V
5A
0 ~ 5A
60W
11 ~ 13V
CONSTANT CURRENT REGION
Note.7
8.4 ~ 12V
15V
LPS
PLN-60-20
20V
14 ~ 20V
3A
0 ~ 3A
60W
1.8Vp-p
18 ~ 22V
( for 48V only)
( except for 48V )
IP64
PLN-60-36
36V
25.2 ~ 36V
1.7A
0 ~ 1.7A
61W
3.6Vp-p
32.5 ~ 39V
PLN-60-48
48V
33.6 ~ 48V
1.3A
0 ~ 1.3A
62.5W
4.6Vp-p
43.6 ~ 51.8V
PLN-60-15
10.5 ~15V
4A
0 ~ 4A
60W
2.4Vp-p
13.8 ~ 16.2V
PLN-60-24
24V
16.8 ~24V
2.5A
0 ~ 2.5A
60W
2.7Vp-p
22 ~ 26V
PLN-60-27
27V
18.9 ~27V
2.3A
0 ~ 2.3A
62.1W
2.7Vp-p
25 ~ 30V
RIPPLE & NOISE (max.)
Note.2
2Vp-p
VOLTAGE ADJ. RANGE
Note.6
Can be adjusted by internal potential meter SVR1
10%
3.0%
5.0%
1500ms / 230VAC 3000ms / 115VAC at full load
CURRENT ADJ. RANGE
Note.6
3% ~ -25%. Can be adjusted by internal potential meter SVR2
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
SETUP TIME
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR
INPUT
EFFICIENCY(Typ.)
AC CURRENT
INRUSH CURRENT(max.)
LEAKAGE CURRENT
OVER CURRENT
SHORT CIRCUIT
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
Note.5
90 ~ 264VAC
127 ~ 370VDC
47 ~ 63Hz
PF 0.9 at 75 ~ 100% load, 115VAC / 230VAC
83%
0.8A/115VAC
40A/230VAC
95 ~ 110%
84.5%
0.4A/230VAC
86.5%
86.5%
87%
87%
88%
<0.75mA / 240VAC
130% (max)
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Note.4
Hiccup mode, recovers automatically after fault condition is removed.
13.8 ~ 16V
17.5 ~ 21V
22.8 ~ 25V
28 ~ 32V
Protection type : Shut down o/p voltage, re-power on to recover
95
10
(TSW1) detect on heatsink of power transistor
(Refer to output load derating curve)
, 10 ~ 95% RH
(0 ~ 50
)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-30 ~ +50
-40 ~ +80
0.03%/
20 ~ 95% RH non-condensing
31 ~ 35V
41 ~ 46V
54 ~ 60V
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL1310 Class 2, TUV EN61347-1, EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved
I/P-O/P:3.75KVAC
I/P-FG:1.88KVAC
O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
EMC
EMI CONDUCTION & RADIATION
Compliance to EN55015, EN55022 (CISPR22) Class B
Compliance to EN61000-3-2 Class C ( 75% load) ; EN61000-3-3
HARMONIC CURRENT
EMS IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024,EN61547, light industry level, criteria A
497.8Khrs min.
MIL-HDBK-217F (25
)
181*61.5*35mm (L*W*H)
0.5Kg; 24pcs/13Kg/0.75CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
Direct connecting to LEDs is not suggested for models with “RIPPLE & NOISE” > 10% and using additional drivers is highly recommended.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to OLP characteristics.
5. Derating may be needed under low input voltage. Please check the derating curve for more details.
6. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB.
7. Constant current operation region is within 70% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
File Name:PLN-60-SPEC 2009-03-04