欢迎访问ic37.com |
会员登录 免费注册
发布采购

PPS-125-12 参数 Datasheet PDF下载

PPS-125-12图片预览
型号: PPS-125-12
PDF下载: 下载PDF文件 查看货源
内容描述: 125W单路输出带PFC功能 [125W Single Output with PFC Function]
分类和应用: 功率因数校正
文件页数/大小: 2 页 / 279 K
品牌: MEANWELL [ MEAN WELL ENTERPRISES CO., LTD. ]
 浏览型号PPS-125-12的Datasheet PDF文件第2页  
125W Single Output with PFC Function
Features :
PPS-125
series
Universal AC input / Full range
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage
PWM control and regulated
High power density 6.117W/inch
3
Built-in remote sense function
LED indicator for power on
100% full load burn-in test
125W with 18CFM FAN
5"x3" compact size
3 years warranty
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
PPS-125-3.3
3.3V
20A
PPS-125-5
5V
20A
0 ~ 20A
0 ~ 25A
100W
125W
100mVp-p
4.75 ~ 5.25V
2.0%
0.5%
1.0%
PPS-125-12
12V
8.5A
0 ~ 8.5A
0 ~ 10.5A
102W
126W
100mVp-p
PPS-125-13.5 PPS-125-15
13.5V
7.5A
0 ~ 7.5A
0 ~ 9.3A
101.25W
125.55W
100mVp-p
15V
6.7A
0 ~ 6.7A
0 ~ 8.4A
100.5W
126W
100mVp-p
PPS-125-24
24V
4.2A
0 ~ 4.2A
0 ~ 5.2A
100.8W
124.8W
150mVp-p
PPS-125-27
27V
3.8A
0 ~ 3.8A
0 ~ 4.6A
102.6W
124.2W
150mVp-p
PPS-125-48
48V
2.1A
0 ~ 2.1A
0 ~ 2.6A
100.8W
124.8W
250mVp-p
CURRENT RANGE (convection)
0 ~ 20A
CURRENT RANGE (18CFM FAN)
0 ~ 25A
RATED POWER (convection)
66W
RATED POWER (18CFM FAN)
82.5W
OUTPUT
RIPPLE & NOISE (max.)
Note.2
100mVp-p
3.13 ~ 3.46V
VOLTAGE TOLERANCE
Note.3
2.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
INPUT
EFFICIENCY (Typ.)
AC CURRENT
(Typ.)
115VAC
230VAC
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 4)
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
0.5%
1.0%
24ms/230VAC
90 ~ 264VAC
47~63Hz
VOLTAGE ADJ. RANGE
11.40 ~ 12.60V 12.82 ~ 14.17V 14.25 ~ 15.75V 22.80 ~ 25.20V 25.65 ~ 28.35V 45.60 ~ 50.40V
2.0%
2.0%
2.0%
1.0%
1.0%
1.0%
0.5%
1.0%
0.5%
1.0%
0.5%
1.0%
0.5%
1.0%
0.5%
1.0%
0.5%
1.0%
1000ms, 30ms/230VAC
2000ms, 30ms/115VAC at full load
24ms/115VAC at full load
127 ~ 370VDC
PF>0.98/115VAC at full load
80%
80%
80%
83%
83%
84%
PF>0.93/230VAC
70%
1.2A
79%
1.7A
0.6A
0.75A
COLD START 24A/230VAC
<2mA / 240VAC
130 ~ 160% rated output power
Protection type : Fold back current limiting, recovers automatically after fault condition is removed
3.63 ~ 4.45V
5.5 ~ 6.75V
13.8 ~ 16.2V
15.5 ~ 20.25V 17.25 ~ 20.25V 27.6 ~ 32.4V
31.05 ~ 36.45V 57.6 ~ 67.2V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-20 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
0.05%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
111.7Khrs min. MIL-HDBK-217F (25
127*76.2*34.6mm (L*W*H)
0.37Kg; 36pcs/14.3Kg/0.79CUFT
)
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Heat Sink HS1,HS2 & HS3 can not be shorted.
File Name:PPS-125-SPEC 2011-08-18