欢迎访问ic37.com |
会员登录 免费注册
发布采购

PPS-200-24 参数 Datasheet PDF下载

PPS-200-24图片预览
型号: PPS-200-24
PDF下载: 下载PDF文件 查看货源
内容描述: 200W单路输出带PFC功能 [200W Single Output with PFC Function]
分类和应用: 功率因数校正
文件页数/大小: 2 页 / 331 K
品牌: MEANWELL [ MEAN WELL ENTERPRISES CO., LTD. ]
 浏览型号PPS-200-24的Datasheet PDF文件第2页  
200W Single Output with PFC Function
Features :
PPS-200
series
Universal AC input / Full range
Built-in active PFC function
High efficiency up to 90% (typ)
Protections: Short circuit / Overload / Over voltage / Over temperature
PWM control and regulated
High power density 9.78W/inch
3
5"x3" compact size
Built-in remote sense function
ZVS technology to reduce power dissipation
Free air convection for 150W and 200W with 20.5 CFM forced air
3 years warranty
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
PPS-200-5
5V
36A
PPS-200-12
12V
16.6A
0 ~ 12.5A
0 ~ 16.6A
150W
199.2W
100mVp-p
10.8 ~ 13.2V
3.0%
0.5%
1.0%
PPS-200-15
15V
13.3A
0 ~ 10A
0 ~ 13.3A
150W
199.5W
100mVp-p
13.5 ~ 16.5V
3.0%
0.5%
1.0%
2500ms, 60ms/115VAC at full load
PPS-200-24
24V
8.3A
0 ~ 6.25A
0 ~ 8.3A
150W
199.2W
150mVp-p
21.6 ~ 26.4V
2.0%
0.5%
1.0%
PPS-200-27
27V
7.4A
0 ~ 5.56A
0 ~ 7.4A
150W
199.8W
150mVp-p
24.3 ~ 30V
2.0%
0.5%
1.0%
PPS-200-48
48V
4.167A
0 ~ 3.13A
0 ~ 4.167A
150.24W
200.016W
250mVp-p
43.2 ~ 52.8V
2.0%
0.5%
1.0%
CURRENT RANGE (convection)
0 ~ 26A
CURRENT RANGE (20.5CFM FAN)
0 ~ 36A
RATED POWER (convection)
130W
RATED POWER (20.5CFM FAN)
180W
OUTPUT
RIPPLE & NOISE (max.)
Note.2
100mVp-p
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 4)
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
4.5 ~ 5.5V
VOLTAGE TOLERANCE
Note.3
4.0%
0.5%
1.0%
1200ms, 60ms/230VAC
90 ~ 264VAC
47 ~ 63Hz
PF>0.93/230VAC
86%
11ms/230VAC/115VAC at full load
127 ~ 370VDC
PF>0.98/115VAC at full load
89%
89%
89%
89%
90%
2.2A/115VAC
1.2A/230VAC
COLD START 70A/230VAC
<2mA / 240VAC
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.6 ~ 7.25V
13.8 ~ 16.2V
17.25 ~ 20.25V
27.6 ~ 32.4V
31.05 ~ 36.45V
57.6 ~ 67.2V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
110
5 (TSW1) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-20 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
0.05%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
108.4Khrs min. MIL-HDBK-217F (25
127*76.2*34.6mm (L*W*H)
0.37Kg; 36pcs/14.3Kg/0.79CUFT
)
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Heat Sink HS1,HS2 can not be shorted.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
File Name:PPS-200-SPEC 2011-11-29