欢迎访问ic37.com |
会员登录 免费注册
发布采购

RS-100-24 参数 Datasheet PDF下载

RS-100-24图片预览
型号: RS-100-24
PDF下载: 下载PDF文件 查看货源
内容描述: 100W单路输出开关电源 [100W Single Output Switching Power Supply]
分类和应用: 开关
文件页数/大小: 2 页 / 387 K
品牌: MEANWELL [ MEAN WELL ENTERPRISES CO., LTD. ]
 浏览型号RS-100-24的Datasheet PDF文件第2页  
100W Single Output Switching Power Supply
Features :
Universal AC input / Full range
RS-100
series
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105
long life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
RS-100-3.3
3.3V
20A
0 ~ 20A
66W
RS-100-5
5V
16A
0 ~ 16A
80W
80mVp-p
4.75 ~ 5.5V
2.0%
0.5%
1.0%
RS-100-12
12V
8.5A
0 ~ 8.5A
102W
120mVp-p
11.4 ~ 13.2V
1.0%
0.5%
0.5%
RS-100-15
15V
7A
0 ~ 7A
105W
120mVp-p
14.25 ~ 16.5V
1.0%
0.5%
0.5%
RS-100-24
24V
4.5A
0 ~ 4.5A
108W
120mVp-p
22.8 ~ 26.4V
1.0%
0.5%
0.5%
RS-100-48
48V
2.3A
0 ~ 2.3A
110.4W
200mVp-p
45.6 ~ 52.8V
1.0%
0.5%
0.5%
RIPPLE & NOISE (max.)
Note.2
80mVp-p
3.2V ~ 3.5V
VOLTAGE TOLERANCE
Note.3
3.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER LOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY & ISOLATION RESISTANCE
EMC
(Note 6)
Note.4
Note.5
0.5%
2.0%
500ms, 20ms/230VAC
100ms/230VAC
88 ~ 264VAC
47 ~ 63Hz
74%
1200ms, 30ms/115VAC at full load
18ms/115VAC at full load
125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
77%
81%
82%
84%
84%
2.5A/115VAC
1.5A/230VAC
COLD START 40A/230VAC
<2mA / 240VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8 ~ 4.45V
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-25 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
27.6 ~ 32.4V
55.2 ~ 64.8V
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION
Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criteria A
EMS IMMUNITY
MTBF
DIMENSION
PACKING
260.8Khrs min. MIL-HDBK-217F (25
159*97*38mm (L*W*H)
0.6Kg; 24pcs/15.4Kg/0.7CUFT
)
OTHERS
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
File Name:RS-100-SPEC 2005-09-13