100W Single Output Switching Power Supply
Features :
S-100F
series
AC input range selectable by switch
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 83KHz
2 years warranty
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
EMC
(Note 4)
(for 24V only)
S-100F-5
5V
20A
0 ~ 20A
100W
4.5 ~ 5.5V
2.0%
0.5%
1.0%
20ms at full load
88 ~ 132VAC/176 ~ 264VAC selected by jumper or switch
47 ~ 63Hz
76%
78%
80%
81%
83%
84%
3.15A/115VAC
1.5A/230VAC
COLD START 20A/115VAC
40A/230VAC
<1mA / 240VAC
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75V
8.63 ~ 10.13V
13.8 ~ 16.2V
17.25 ~ 20.25V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +60
-20 ~ +85
(Refer to output load derating curve)
, 10 ~ 95% RH
20 ~ 90% RH non-condensing
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
CSA60950-1 (for 24V only), UL1012, UL60950-1, TUV EN60950-1 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
27.6 ~ 32.4V
55.2 ~ 64.8V
248 ~ 370VDC
S-100F-7.5
7.5V
13.5A
0 ~ 13.5A
101W
125mVp-p
6.75 ~ 8.25V
1.0%
0.5%
0.5%
S-100F-12
12V
8.5A
0 ~ 8.5A
102W
125mVp-p
10.8 ~ 13.2V
1.0%
0.5%
0.5%
S-100F-15
15V
6.7A
0 ~ 6.7A
100.5W
125mVp-p
13.5 ~ 16.5V
1.0%
0.5%
0.5%
S-100F-24
24V
4.5A
0 ~ 4.5A
108W
150mVp-p
21.6 ~ 26.4V
1.0%
0.5%
0.5%
S-100F-48
48V
2.2A
0 ~ 2.2A
105.6W
150mVp-p
43.2 ~ 52.8V
1.0%
0.5%
0.5%
RIPPLE & NOISE (max.)
Note.2
100mVp-p
1000ms, 30ms at full load
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION
Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
314.9K hrs min. MIL-HDBK-217F (25
199*98*38mm (L*W*H)
0.65Kg; 20pcs/14.2Kg/0.8CUFT
)
OTHERS
NOTE
DIMENSION
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:S-100F-SPEC 2007-01-23