 浏览型号MLX90614ESF-DAC的Datasheet PDF文件第6页浏览型号MLX90614ESF-DAC的Datasheet PDF文件第7页浏览型号MLX90614ESF-DAC的Datasheet PDF文件第8页浏览型号MLX90614ESF-DAC的Datasheet PDF文件第9页浏览型号MLX90614ESF-DAC的Datasheet PDF文件第11页浏览型号MLX90614ESF-DAC的Datasheet PDF文件第12页浏览型号MLX90614ESF-DAC的Datasheet PDF文件第13页浏览型号MLX90614ESF-DAC的Datasheet PDF文件第14页  
MLX90614 family  
Single and Dual Zone  
Infra Red Thermometer in TO-39  
8 Detailed description  
8.1 Block diagram  
81101  
OPA  
ADC  
DSP  
PWM  
t°  
STATE MACHINE  
Voltage  
Regulator  
90302  
Figure 3: block diagram  
8.2 Signal processing principle  
The operation of the MLX90614 is controlled by an internal state machine, which controls the measurements  
and calculations of the object and ambient temperatures and does the post-processing of the temperatures to  
output them through the PWM output or the SMBus compatible interface.  
The ASSP supports 2 IR sensors (second one not implemented in the MLX90614xAx).The output of the IR  
sensors is amplified by a low noise low offset chopper amplifier with programmable gain, converted by a  
Sigma Delta modulator to a single bit stream and fed to a powerful DSP for further processing. The signal is  
treated by programmable (by means of EEPROM contend) FIR and IIR low pass filters for further reduction of  
the band width of the input signal to achieve the desired noise performance and refresh rate. The output of  
the IIR filter is the measurement result and is available in the internal RAM. 3 different cells are available:  
One for the on-board temperature sensor (on chip PTAT or PTC) and 2 for the IR sensors.  
Based on results of the above measurements, the corresponding ambient temperature Ta and object  
temperatures To are calculated. Both calculated temperatures have a resolution of 0.01 ˚C. The data for Ta  
and To can be read in two ways: Reading RAM cells dedicated for this purpose via the 2-wire interface  
(0.02°C resolution, fixed ranges), or through the PWM digital output (10 bit resolution, configurable range).  
In the last step of the measurement cycle, the measured Ta and To are rescaled to the desired output  
resolution of the PWM) and the recalculated data is loaded in the registers of the PWM state machine, which  
creates a constant frequency with a duty cycle representing the measured data.  
3901090614  
Rev 003  
Page 10 of 40  
Data Sheet  
03/Oct/2007