FAST RECOVERY RECTIFIER
FR801 THRU FR806
FEATURES
•
•
•
•
•
•
•
•
VOLTAGE RANGE
CURRENT
50 to 1000 Volts
8.0 Ampere
Glass passivated chip junction
Low cost construction
Fast switching for high efficiency
Low reverse leakage
High forward surge current capacity
High temperature soldering guaranteed
260℃/10 second,0.375″(9.5mm)lead length
at 5 lbs (2.3kg) tension
TO-220AC
MECHANICAL DATA
•
•
•
•
•
•
Case: Transfer molded plastic
Epoxy: UL94V-0 rate flame retardant
Polarity: Color band denotes cathode end
Lead: Plated axial lead, solderable per MIL-STD-202E method 208C
Mounting position: Any
Weight: 0.064ounce, 1.81 gram
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25℃ ambient temperature unless otherwise specified
Single Phase, half wave, 60Hz, resistive or inductive load
For capacitive load derate current by 20%
SYMBOLS FR801
FR802
Maximum Repetitive Peak Reverse Voltage
V
RRM
50
100
Maximum RMS Voltage
V
RMS
35
70
Maximum DC Blocking Voltage
V
DC
50
100
Maximum Average Forward Rectified Current
0.375″(9.5mm) lead length at Tc=100℃
Peak Forward Surge Current
8.3ms single half sine wave superimposed on
rated load (JEDEC method)
Maximum Instantaneous Forward Voltage at 8.0A
Maximum DC Reverse Current at rated T
A
= 25℃
DC Blocking Voltage per element
T
A
= 100℃
Maximum Reverse Recovery Time (NOTE 3)Tj=25℃
Typical Junction Capacitance (NOTE 1)
Typical Thermal Resistance (NOTE 2)
Operating and Storage Temperature Range
Storage Temperature Range
•
•
•
FR803
200
140
200
8.0
200
1.3
10
500
FR804
400
280
400
FR805
600
420
600
FR806
800
560
800
UNIT
Volts
Volts
Volts
Amps
Amps
Volts
µA
I
(AV)
I
FSM
V
F
I
R
t
rr
C
J
R
θJC
T
J
T
STG
150
250
50
3.0
(-55 to +150)
(-55 to +150)
500
nS
pF
℃
/W
℃
℃
Notes:
1. Measured at 1.0 MHz and applied reverse voltage of 4.0 Volts.
2. Thermal Resistance from Junction to CASE
3. Reverse Recovery Test Conditions: I
F
=0.5A, I
R
=1.0A, I
RR
=0.25A
E-mail: