欢迎访问ic37.com |
会员登录 免费注册
发布采购

LM4041CIM3-ADJ 参数 Datasheet PDF下载

LM4041CIM3-ADJ图片预览
型号: LM4041CIM3-ADJ
PDF下载: 下载PDF文件 查看货源
内容描述: 精密微功耗并联型电压基准 [Precision Micropower Shunt Voltage Reference]
分类和应用:
文件页数/大小: 16 页 / 815 K
品牌: MICREL [ MICREL SEMICONDUCTOR ]
 浏览型号LM4041CIM3-ADJ的Datasheet PDF文件第5页浏览型号LM4041CIM3-ADJ的Datasheet PDF文件第6页浏览型号LM4041CIM3-ADJ的Datasheet PDF文件第7页浏览型号LM4041CIM3-ADJ的Datasheet PDF文件第8页浏览型号LM4041CIM3-ADJ的Datasheet PDF文件第10页浏览型号LM4041CIM3-ADJ的Datasheet PDF文件第11页浏览型号LM4041CIM3-ADJ的Datasheet PDF文件第12页浏览型号LM4041CIM3-ADJ的Datasheet PDF文件第13页  
LM4040/4041
Micrel, Inc.
Boldface limits apply for T
A
= T
J
= T
MIN
to T
MAX
; all other limits T
A
= T
J
= 25°C. The grades C and D designate initial Reverse Break-
down Voltage tolerance of ±0.5% and ± 1.0%, respectively.
Symbol
V
R
Parameter
Reverse Breakdown Voltage
Reverse Breakdown Voltage
Tolerance
(Note 7)
Minimum Operating Current
Conditions
I
R
= 100µA
45
I
R
= 100µA
Typical
(Note 5)
1.225
±12
±24
65
70
±150
LM4041DIM3
Limits
(Note 6)
Units
(Limit)
V
mV (max)
mV (max)
µA
µA (max)
µA (max)
ppm/°C
ppm/°C (max)
ppm/°C (max)
mV
mV (max)
mV (max)
mV
mV (max)
mV (max)
Ω
Ω (max)
µV
RMS
ppm
LM4041-1.2 Electrical Characteristics
(Note 4)
I
RMIN
ΔV
R
/ΔT
ΔV
R
/ΔI
R
Average Reverse Breakdown
Voltage Temperature
Coefficient
Reverse Breakdown Voltage
Change with Operating
Current Change
I
RMIN
≤ I
R
1mA
1mA ≤ I
R
15mA
I
R
= 10mA
I
R
= 1mA
I
R
= 100µA
±20
±15
±15
0.7
2.0
2.5
8.0
10.0
2.0
2.5
Z
R
e
N
ΔV
R
Reverse Dynamic Impedance
Wideband Noise
Reverse Breakdown Voltage
Long Term Stability
I
R
= 100µA
10Hz ≤ f ≤ 10kHz
t = 1000hrs
T = 25°C ±0.1°C
I
R
= 100µA
I
R
= 1mA, f = 120Hz
I
AC
= 0.1 I
R
0.5
20
120
Note 4.
Note 5.
Note 6.
Note 7.
Specification for packaged product only.
Typicals are at T
J
= 25°C and represent most likely parametric norm.
Limits are 100% production tested at 25°C. Limits over temperature are guaranteed through correlation using Statistical Quality Control (SQL)
methods.
The boldface (over temperature limit for Reverse Breakdown Voltage Tolerance is defined as the room temperature Reverse Breakdown Volt-
age Tolerance ±[(ΔV
R
/ΔT)(65°C)(V
R
)]. ΔV
R
/ΔT is the V
R
temperature coefficient, 65°C is the temperature range from –40°C to the reference
point of 25°C, and V
R
is the reverse breakdown voltage. The total over temperature tolerance for the different grades follows:
C-grade: ±1.15% = ±0.5% ±100ppm/°C
×
65°C
D-grade: ±1.98% = ±1.0% ±150ppm/°C
×
65°C
Example: The C-grade LM4040-2.5 has an over temperature Reverse Breakdown Voltage tolerance of ±2.5
×
1.15% = ±29mV.
March 2005
9
M9999-031805